Jiangsu Changmei Medical Device

Estudo de caso Produtos relacionados Conhecimento relacionado Casos relacionados
Precisa de ajuda? Solicitar orçamento

Treinamento VicoMeter no local

Jiangsu Changmei Medical Device
Jiangsu Changmei Medical Device
Jiangsu Changmei Medical Device
Jiangsu Changmei Medical Device
  • Jiangsu Changmei Medical Device
  • Jiangsu Changmei Medical Device
  • Jiangsu Changmei Medical Device
  • Jiangsu Changmei Medical Device

Perfil do cliente

O cliente adquiriu o analisador de umidade residual Karl Fischer VicoMeter WKT-A9 'Exquisite' juntamente com o forno Karl Fischer WKT-V1 correspondente. Com base no princípio coulométrico de Karl Fischer, o VicoMeter WKT-A9 'Exquisite' determina rapidamente a umidade residual em amostras até 0,001 ppm e pode medir a umidade residual em sólidos, líquidos e pós em até 1 minuto. O instrumento possui impressora integrada e pode armazenar 500 conjuntos de dados para consulta e impressão em tempo real. Instruções inovadoras no estilo de navegação e um manual eletrônico integrado tornam a operação simples. Em conformidade com diversas normas nacionais e internacionais de determinação de umidade, o WKT-A9 inclui oito fórmulas de cálculo de umidade integradas e seis métodos de determinação para atender às necessidades de diversos setores. É amplamente utilizado nas indústrias química, de petróleo, farmacêutica, de energia, alimentícia, de pesquisa e de ensaios.

WKT-A9 Analisador de umidade residual Karl Fischer coulométrico

WKT-A9 Analisador de umidade residual Karl Fischer coulométrico

WKT-A9 Analisador de umidade residual Karl Fischer coulométrico

Princípio coulométrico (coulometria), ideal para ensaios em nível de traços; tela touchscreen colorida de 5 polegadas com operação inteligente, cálculo automático dos resultados e IDs de amostra livremente configuráveis; atende a diversos padrões nacionais e é adequado a praticamente todos os setores.

  • 8 fórmulas de cálculo de umidade, 6 métodos de determinação e 8 algoritmos de detecção de ponto final

  • Compensação automática de deriva, subtração automática da umidade ambiente e de fundo e alertas de autodiagnóstico de falhas

  • Início com um toque para resultados confiáveis

  • Automação excepcional — conexão perfeita com o forno Karl Fischer para amostras difíceis

  • Interface RS232 para conexão a PC, impressora, PLC ou LIMS


Sistema de medição de umidade com forno Karl Fischer WKT-V2

Sistema de medição de umidade com forno Karl Fischer WKT-V2

Sistema de medição de umidade com forno Karl Fischer WKT-V2

Ao medir a umidade com um analisador Karl Fischer, a maioria das amostras pode ser adicionada diretamente à célula geradora/célula de titulação para um ensaio simples e exato. Algumas amostras, no entanto, não podem ser adicionadas diretamente porque sua umidade não é liberada naturalmente ou porque reagem lateralmente com o reagente Karl Fischer — por exemplo, pós, grânulos, pastas e sais inorgânicos oxidantes.

Para as amostras que não podem ser adicionadas diretamente à célula, a combinação com o forno Karl Fischer WKT-V2 para extração em fase gasosa é a solução ideal. A amostra é colocada em um frasco, levada ao forno e aquecida a uma temperatura específica (até 300 ˚C); a umidade é extraída e conduzida para a célula por ar seco ou nitrogênio e, então, medida com precisão.


VicoMeter no local do cliente

Após chegar ao local do cliente, o engenheiro técnico da VicoMeter conferiu a lista de instrumentos com o cliente e iniciou a instalação assim que tudo foi confirmado. A instalação transcorreu bem, mas o engenheiro encontrou um problema durante a verificação do instrumento: após a conexão do nitrogênio, a taxa de eletrólise subiu para cerca de 6 e não diminuía, e o instrumento demorava muito a estabilizar. Como o reagente havia sido recém-aberto, um problema de reagente foi descartado. Duas possibilidades foram consideradas: 1. a pureza do nitrogênio do cliente não estava dentro do padrão; 2. a peneira molecular do cliente havia absorvido umidade devido às chuvas frequentes recentes. Para verificar, o engenheiro conectou o nitrogênio diretamente ao forno Karl Fischer sem passá-lo pela peneira molecular — e a taxa de eletrólise caiu imediatamente para cerca de 1,2. O engenheiro concluiu, portanto, que a peneira molecular havia absorvido umidade, retirou-a e secou-a em estufa de temperatura constante a 120 °C por 2 horas. Após a remontagem, a taxa de eletrólise estabilizou em cerca de 1,6 e o instrumento rapidamente atingiu o equilíbrio. A aceitação e os testes subsequentes transcorreram bem, e o cliente ficou muito satisfeito com o instrumento.

Perfil do cliente

Sistema de medição de umidade com forno Karl Fischer WKT-V2

Jiangsu Changmei Medical Device

(Clique na imagem para ampliar)

Jiangsu Changmei Medical Device

Jiangsu Changmei Medical Devices Co., Ltd. was established on July 17, 2013, with its registered address at No. 27 Xinke West Road, Luoyang Town, Wujin District, and Yuan Luxin as its legal representative. Its business scope includes: manufacture of medical devices (Class III products produced within the scope approved in the Medical Device Manufacturing Enterprise License); R&D, manufacture, and sales of electromechanical equipment and accessories and computer hardware and software; import and export of various goods and technologies on a self-operated or agency basis (except those restricted or prohibited by the state); production of Class I medical devices; production of Class II medical devices; production and sales of daily-use masks (non-medical); production and sales of labor protection supplies; and sales of industrial textile finished products (for items subject to approval, business activities may only be carried out after approval by the relevant departments).

Produtos relacionados

Conhecimento relacionado

Analisadores de umidade Karl Fischer Analisadores de umidade Karl Fischer

O analisador de umidade Karl Fischer é um instrumento projetado com base no método Karl Fischer para medir o teor de umidade em materiais. Também é conhecido como medidor de umidade Karl Fischer, titulador de umidade Karl Fischer totalmente automático, analisador inteligente de umidade residual Karl Fischer ou medidor de umidade pelo método Fischer, e existe em dois tipos: coulométrico e volumétrico (titulométrico).

Qual é a diferença entre a titulação Karl Fischer coulométrica e a volumétrica? Qual é a diferença entre a titulação Karl Fischer coulométrica e a volumétrica?

A maior diferença entre os métodos volumétrico e coulométrico é que o I2diferem em sua origem: no método volumétrico, o I2vem do reagente titulante, enquanto no método coulométrico o I2é produzido pela eletrólise de um eletrólito que contém I-é gerado pela eletrólise do eletrólito.

Quais amostras um analisador de umidade Karl Fischer pode testar? Quais amostras um analisador de umidade Karl Fischer pode testar?

Como método clássico de determinação de umidade, a titulação Karl Fischer é adequada para medir água em uma ampla variedade de substâncias orgânicas e inorgânicas. Como os compostos variam em suas propriedades, eles se dividem em duas categorias: os que podem ser analisados diretamente e os que não podem.

Quais padrões de calibração e métodos de verificação estão disponíveis para a determinação de umidade Karl Fischer? Quais padrões de calibração e métodos de verificação estão disponíveis para a determinação de umidade Karl Fischer?

Os analisadores de umidade Karl Fischer VicoMeter são normalmente calibrados e verificados com padrões como soluções padrão de metanol e água, tartarato de sódio hidratado, água destilada (deionizada ou pura) e tolueno saturado com água. Este artigo apresenta as substâncias de calibração, os métodos de calibração e os procedimentos de verificação de exatidão comumente utilizados nos analisadores de umidade Karl Fischer coulométricos e volumétricos da VicoMeter.

Como garantir que a umidade reaja completamente com o reagente Karl Fischer Como garantir que a umidade reaja completamente com o reagente Karl Fischer

Como instrumento profissional para a determinação de umidade, o analisador de umidade Karl Fischer é amplamente utilizado em diversos setores. Garantir que a umidade reaja completamente com o reagente Karl Fischer é a chave para uma medição precisa da umidade nas amostras. Como isso pode ser alcançado? É a pergunta que este artigo responde. Como especialista na área de umidade, a VicoMeter orienta você passo a passo.

Medição da umidade da amostra com um analisador de umidade Karl Fischer Medição da umidade da amostra com um analisador de umidade Karl Fischer

O analisador de umidade Karl Fischer determina rapidamente a umidade residual em amostras e é o método mais profissional para a determinação do teor de umidade.

Casos relacionados

Jinan Bestzyme Bio-Engineering Co., Ltd.
Guangzhou Tianmei Medical Technology Co., Ltd.
Hubei Hongzhong Pharmaceutical Co., Ltd.
Jiangsu Aihoupu Medical Device
Jiangsu Huashen Pharmaceutical Co., Ltd.
Linyi Huanshi Pellet Equipment
Nanjing Haijing Pharmaceutical
Zhenghe Medical

Soluções personalizadas para as reais necessidades do seu negócio

Contato

Produtos vistos recentemente

Contato
+8652389989770
+8613852641385
sales@vicometer.com