WKT-A6 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A6 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 7-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS

Overview Technical Specifications Applicable Industries Related Products

Overview

WKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A6 Karl Fischer Trace Moisture Analyzer Coulometric


Technical Specifications

ModelWKT-A6
Measuring PrincipleKarl Fischercoulometric(coulometric)
Measurement Speed40 μg H2O/s (max)
Measuring Range0.1μg-230mg
Measurement AccuracyError ≤ ±2 μg for water content of 100–1000 μg; error ≤ ±0.2% above 1000 μg (injection error excluded); standard deviation ≤ 0.3%
Resolution0.1 μg H2O
Concentration Units%、ppm、mg/kg
Electrolysis Current0–400 mA adjustable
Water Content (Concentration Range)0-100%
Stirring SpeedStepless touch adjustment
Drift/Blank SubtractionAutomatic subtraction
Special FunctionsAutomatic drift compensation, automatic subtraction of ambient and background moisture, optional PC workstation, and self-diagnostic fault alerts
Display & OperationColor touchscreen
Sample IDFreely configurable sample IDs
Stored Records500 records
PrintingBuilt-in low-power high-speed thermal printer, 56 mm paper width
PrintoutDisplays different content according to the user's measurement formulas and results
Calendar/ClockCurrent time, date, and test time/date displayed and printed
Endpoint IndicationScreen prompt / printout / audible alarm / end-point lamp
Operating EnvironmentTemperature 2 ℃–50 ℃, humidity <90%
Power Consumption≤50W
Unit Dimensions400mm*300mm*150mm
Power Supply220V 50HZ  150W
Weight4.5kg

Applicable Industries

Application Fields of the WKT-A6 Karl Fischer Trace Moisture Analyzer

LiquidChemical industry: alcohols, ethers, acids, benzenes, phenols, organic solvents, and other products suited to Karl Fischer determination.
         Petroleum and power: insulating oil, transformer oil, and other oils.
         Pharmaceutical industry: pharmaceutical raw materials, etc.
         Pesticide industry: emulsifiers, etc.
         Other industries: lithium battery electrolytes, etc.
SolidFreely soluble solids such as various inorganic salts and citric acid
GasGases such as nitrogen, SF6, natural gas, liquefied petroleum gas, Freon, and butadiene
The following industries require a Karl Fischer oven
Insoluble SolidsLithium batteries, plastics, medical, ceramic powders, metal powders, etc.
Other Insoluble SolidsInsoluble solids, easily contaminated and cross-contaminating samples (lubricating greases, aldehydes and ketones), samples that react with Karl Fischer reagent, and samples with slow moisture release

Related Products

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric
WKT-A9P ro Moisture Meter Coulometric WKT-A9P ro Moisture Meter Coulometric
WKT-A8 Automatic Moisture Analyzer Automatic Reagent Exchange WKT-A8 Automatic Moisture Analyzer Automatic Reagent Exchange
WKT-A7 Karl Fischer Moisture Titrator WKT-A7 Karl Fischer Moisture Titrator

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com