Material No.: 2022098898038
Detailed Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min

 

Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Measured ParametersTotal Phosphorus (TP)
Measuring Range0-20 mg/L (segmented)
Detection Limit0.02mg/L
Digestion Conditions125℃,30min

 

Measured ParametersTotal Nitrogen (TN)
Measuring Range0-100 mg/L (segmented)
Detection Limit0.5mg/L
Digestion Conditions125℃,30min

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898053
Detailed Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min

 

Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Measured ParametersTotal Phosphorus (TP)
Measuring Range0-20 mg/L (segmented)
Detection Limit0.02mg/L
Digestion Conditions125℃,30min

 

Measured ParametersTotal Nitrogen (TN)
Measuring Range0-100 mg/L (segmented)
Detection Limit0.5mg/L
Digestion Conditions125℃,30min

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898039
Detailed Specifications
Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898055
Detailed Specifications
Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable lithium battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 0.5 kg
Material No.: 2022098898040
Detailed Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min
Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898056
Detailed Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min
Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable lithium battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 0.5 kg
Material No.: 2022098898041
Detailed Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min

 

Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Measured ParametersTotal Phosphorus (TP)
Measuring Range0-20 mg/L (segmented)
Detection Limit0.02mg/L
Digestion Conditions125℃,30min

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898058
Detailed Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min

 

Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Measured ParametersTotal Phosphorus (TP)
Measuring Range0-20 mg/L (segmented)
Detection Limit0.02mg/L
Digestion Conditions125℃,30min

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable Bluetooth printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable lithium battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 0.5 kg
Material No.: 2022098898042
Detailed Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min

 

Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Measured ParametersTotal Phosphorus (TP)
Measuring Range0-20 mg/L (segmented)
Detection Limit0.02mg/L
Digestion Conditions125℃,30min

 

Measured ParametersTotal Nitrogen (TN)
Measuring Range0-100 mg/L (segmented)
Detection Limit0.5mg/L
Digestion Conditions125℃,30min

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898059
Detailed Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min

 

Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Measured ParametersTotal Phosphorus (TP)
Measuring Range0-20 mg/L (segmented)
Detection Limit0.02mg/L
Digestion Conditions125℃,30min

 

Measured ParametersTotal Nitrogen (TN)
Measuring Range0-100 mg/L (segmented)
Detection Limit0.5mg/L
Digestion Conditions125℃,30min

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable Bluetooth printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable lithium battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 0.5 kg
Material No.: 2022098898043
Detailed Specifications
Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898057
Detailed Specifications
Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable Bluetooth printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable lithium battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 0.5 kg
Material No.: 2022098898045
Detailed Specifications
Measured ParametersTotal Phosphorus (TP)(TP)
Measuring Range0-20mg/L
Detection Limit0.02mg/L
Digestion Conditions125℃,30min
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898060
Detailed Specifications
Measured ParametersTotal Phosphorus (TP)(TP)
Measuring Range0-20mg/L
Detection Limit0.02mg/L
Digestion Conditions125℃,30min
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable Bluetooth printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable lithium battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 0.5 kg
Material No.: 2022098898046
Detailed Specifications
Measured ParametersTotal Nitrogen (TN)(TN)
Measuring Range0-100mg/L
Detection Limit0.5mg/L
Digestion Conditions125℃,30min
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898061
Detailed Specifications
Measured ParametersTotal Nitrogen (TN)(TN)
Measuring Range0-100mg/L
Detection Limit0.5mg/L
Digestion Conditions125℃,30min
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable Bluetooth printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable lithium battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 0.5 kg
Material No.: 2022098898050
Detailed Specifications
Measured ParametersNickel (Ni)
Measuring Range0-4 mg/L (segmented)
Detection Limit0.1mg/L
Digestion ConditionsNo Digestion Required
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898050
Detailed Specifications
Measured ParametersHexavalent Chromium
Measuring Range0-5mg/L
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898055
Detailed Specifications
Measured ParametersTotal Chromium (TCr)
Measuring Range0-5mg/L
Detection Limit0.01mg/L
Digestion Conditions125℃,30min
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898052
Detailed Specifications
Measured ParametersCopper (Cu)
Measuring Range0-50 mg/L (segmented)
Detection Limit0.05mg/L
Digestion ConditionsNo Digestion Required
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898053
Detailed Specifications
Measured ParametersZinc (Zn)
Measuring Range0-15mg/L
Detection Limit0.05mg/L
Digestion ConditionsNo Digestion Required
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg
Material No.: 2022098898053
Detailed Specifications
Measured ParametersIron (Fe)
Measuring Range0-50mg/L
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required
Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterBuilt-in thermal printer
User InterfaceChinese/English (optional)
Power SupplyAC(220V±10%),50Hz
Display5-inch color LCD
Power5W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions348mm*250mm*145mm
Instrument WeightMain unit < 2.6 kg; digestion unit: 6 kg

Related Products

WKT-70P Portable Moisture Analyzer WKT-70P Portable Moisture Analyzer
VM-210A Portable Moisture Analyzer VM-210A Portable Moisture Analyzer
VM-W Portable Moisture Analyzer VM-W Portable Moisture Analyzer
VM-P Portable Moisture Analyzer VM-P Portable Moisture Analyzer

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com