WKT-S550C Portable COD Analyzer

WKT-S550C Portable COD Analyzer

The WKT-S550C Portable COD, Ammonia Nitrogen & Total Phosphorus Analyzer is a professional ammonia nitrogen testing instrument designed and manufactured by VicoMeter specifically for industrial wastewater testing. Developed in accordance with HJ/T 399-2007 “Water Quality — Determination of Chemical Oxygen Demand — Rapid Digestion Spectrophotometric Method”, HJ 535-2009 “Water Quality — Determination of Ammonia Nitrogen — Nessler's Reagent Spectrophotometry”, and GB 11893-89 “Water Quality — Determination of Total Phosphorus — Ammonium Molybdate Spectrophotometric Method”, it is compact and portable, delivering reliable and stable results — a trusted assistant for industrial wastewater testing.

The WKT-S550C COD, Ammonia Nitrogen & Total Phosphorus Analyzer integrates VicoMeter's proven water quality analysis technologies into a more complete analysis system. Its multi-channel design, integrated digestion-and-colorimetry tube, mature colorimetric technology, and stable system combined with proprietary algorithms make operation simpler, testing faster, and results more stable and reliable.

VicoMeter is an expert in analysis and testing, providing fast, targeted industry solutions for different users.

Product Details Technical Specifications Related Products

Product Details

WKT-S550C COD, Ammonia Nitrogen & Total Phosphorus Analyzer

WKT-S550C COD, Ammonia Nitrogen & Total Phosphorus Analyzer

(Click image to enlarge)

Instrument Overview

The WKT-S550C Portable COD, Ammonia Nitrogen & Total Phosphorus Analyzer is a professional ammonia nitrogen testing instrument designed and manufactured by VicoMeter specifically for industrial wastewater testing. Developed in accordance with HJ/T 399-2007 “Water Quality — Determination of Chemical Oxygen Demand — Rapid Digestion Spectrophotometric Method”, HJ 535-2009 “Water Quality — Determination of Ammonia Nitrogen — Nessler's Reagent Spectrophotometry”, and GB 11893-89 “Water Quality — Determination of Total Phosphorus — Ammonium Molybdate Spectrophotometric Method”, it is compact and portable, delivering reliable and stable results — a trusted assistant for industrial wastewater testing.

The WKT-S550C COD, Ammonia Nitrogen & Total Phosphorus Analyzer integrates VicoMeter's proven water quality analysis technologies into a more complete analysis system. Its multi-channel design, integrated digestion-and-colorimetry tube, mature colorimetric technology, and stable system combined with proprietary algorithms make operation simpler, testing faster, and results more stable and reliable.

VicoMeter is an expert in analysis and testing, providing fast, targeted industry solutions for different users.

Instrument Features

Wide Range of Applications

This instrument is widely used in emergency monitoring, industrial wastewater, domestic sewage, wastewater treatment, pharmaceuticals and chemicals, food, beverages, textile printing and dyeing, electroplating, papermaking, petroleum and metallurgy, river treatment, research institutes, universities, and other fields.

Guided Operation

The interactive human-machine interface features prompt functions that indicate the next step, intelligently guiding users through the operation with direct readout of test results.

Outlier Elimination

For each data set, the instrument measures the water sample 10 times, removes outliers, and averages the results to reduce measurement error, while flagging any abnormal results.

Reduced Interference

Mature colorimetric technology and a stable system combined with proprietary algorithms minimize the impact of dirty, scratched, or flawed glass tubes (including fingerprints) on results. Paired with VicoMeter's dedicated integrated digestion-colorimetric tubes, stability is no longer a challenge.

Flexible Connectivity

Equipped with one Ethernet, one USB, and one Mini USB port, the instrument easily connects to a computer for data upload, and data can also be uploaded over the LAN via the Ethernet interface, facilitating daily water quality management and analysis and providing data support for the stable operation of wastewater treatment;

Favorite Programs

The favorite programs function lets users add frequently used test programs to their user programs for quick access, avoiding the inefficiency of searching through program lists.

Selectable Measurement Modes

Built-in fast measurement and stable measurement modes allow users to freely choose between speed and accuracy.

Data Processing

The instrument features printing and data storage. Results can be printed immediately (optional Bluetooth printer) or printed from historical records. With built-in storage for 30,000 sets of historical test data, users can retrieve data anytime or upload it to a PC for unlimited permanent storage.

Operating Principle

VicoMeter's integrated digestion-colorimetric tubes work seamlessly with the rapid water quality analyzer and are compatible with φ16 mm and φ25 mm cuvettes.

● Testing complies with national, industry, or international standards.

● Built-in standard test programs, expandable, including but not limited to the following parameters

  • - COD (Chemical Oxygen Demand)

  • - CODmn (Permanganate Index)

  • - Ammonia Nitrogen (NH3-N)

  • - Total Phosphorus (TP)(TP)

  • - Total Nitrogen (TN)(TN)

  • - Turbidity (NTU)

  • - Total Chromium (TCr)

  • - Hexavalent Chromium(Cr 6+)

  • - Copper (Cu)

  • - Nickel (Ni)

  • - Zinc (Zn)

  • - Iron (Fe)

  • ……

Working Principle Diagram of the WKT-S550C COD, Ammonia Nitrogen & Total Phosphorus Analyzer

Working Principle Diagram of the COD, Ammonia Nitrogen & Total Phosphorus Analyzer

(Click image to enlarge)

Working Principle

1. Multi-Channel Light Source System

The multi-channel light source system uses fixed wavelengths, eliminating the need for wavelength adjustment, with no mutual interference between light sources.

2. Integrated Digestion-Colorimetric Tube

Digestion and reading share a single tube, eliminating the need to transfer liquid into a cuvette for measurement—simple, safe, and worry-free.

3. Interference Elimination

Excellent tube uniformity and light transmittance minimize the impact of dirty, scratched, or flawed glass tubes (including fingerprints) on results.

4. Ten Measurements with Outlier Removal

Each data set is measured 10 times; after outliers are removed, the result is calculated using a dedicated algorithm to reduce measurement error.

5. Data Analysis

Sample concentration values are displayed directly, with prompts for abnormal results. Test results can be printed or stored.

6. Data Processing

Data can be uploaded to a computer via USB or LAN, facilitating daily management and analysis and providing data support for the stable operation of wastewater treatment;

WKT-6B Portable Digestion Instrument

WKT-6B Portable Digestion Instrument

(Click image to enlarge)

Companion Digestor

The WKT-6B Multi-Parameter Intelligent Digestion Instrument is a water pollutant digestion device designed by VicoMeter for industrial pollution sources. It supports digestion of routine pollution parameters such as chemical oxygen demand (ammonia nitrogen), total phosphorus (TP), total nitrogen (TN), and total chromium (TCr). Standard ammonia nitrogen, TP, and TN working modes are built in, requiring no additional setup — digestion starts with one touch. Intelligent PID control ensures accurate temperature control with real-time digestion status display. Alarm prompts at each test stage make testing more efficient; a protective cover and over-temperature protection ensure safer digestion; and user-defined functions allow free setting of digestion temperature and time, truly delivering multiple functions in one instrument.

Digestor Features

  • 1. Standard 6-position digester; optional 16-, 25-, or 30-position digesters to better meet user needs.

  • 2. Intelligent PID temperature control and dual over-temperature protection deliver safe, uniform, and fast heating.

  • 3. Built-in standard digestion programs with one-touch design—simply press OK to complete the entire digestion process.

  • 4. Custom mode support allows freely setting digestion temperature and time for one-touch digestion in the desired mode.

  • 5. Suitable for digestion of ammonia nitrogen, total phosphorus, total nitrogen, total chromium, and other items.

Technical Specifications

Test Parameters

Measured ParametersCOD
Measuring Range0-15000 mg/L (segmented)
Chloride Interference1000mg/L
Detection Limit5mg/L
Digestion Conditions165℃,15min

 

Measured ParametersAmmonia Nitrogen
Measuring Range0-50 mg/L (segmented)
Detection Limit0.01mg/L
Digestion ConditionsNo Digestion Required

 

Measured ParametersTotal Phosphorus (TP)
Measuring Range0-20 mg/L (segmented)
Detection Limit0.02mg/L
Digestion Conditions125℃,30min

 

Technical Specifications

Measurement Error≤±5%
Repeatability≤±5%
Optical Stability≤±0.001A/20 min (100,000-hour service life)
Colorimetric MethodColorimetric tube (digestion & colorimetry combined)
Data Processing30,000 records and 96 curves (supports user-defined calibration)
Data TransferUSB cable, LAN, etc.
PrinterOptional portable Bluetooth printer
User InterfaceChinese/English (optional)
Power Supply5V rechargeable lithium battery
DisplayColor LCD
Power0.3W
Ambient Temperature5~40℃
Ambient Humidity≤85%, non-condensing
Unit Dimensions240mm*95mm*80mm
Instrument WeightMain unit < 0.5 kg

 

Expandable Parameters Overview

Test ItemsRange (mg/L)Detection LimitTest Standards
COD0-150005HJ/T 399-2007
Permanganate COD0-100.1GB/T 11892-1989
Ammonia Nitrogen0-500.05HJ535-2009
Total Phosphorus (TP)0-200.02GB/T 11893-1989
Total Nitrogen (TN)0-1000.5Alkaline potassium persulfate oxidation method
Turbidity0-1000NTU0.5GB/T 13200-1991
Suspended Solids (SS)0-5005GB/T 11901-1989
Chromaticity0-500 degrees5GB/T 11903-1989
Hexavalent Chromium0-50.01GB/T 7467-1987
Chromium0-50.01GB/T 7466-1987
Copper0-500.05GB/T 7731.3-2008
Nickel0-40.1GB/T 11910-1989
Zinc0-150.05Xylenol orange method (EPA-recognized method)
Iron0-500.01HJ/T 345─ 2007
Phosphate0-200.02GB/T 11893-1989
Sulfate0-2005HJ/T342-2007
Sulfide0-40.01GB/T 16489-1996
Cyanide0-10.004HJ/T 27-1999
Fluoride0-100.02HJ 488-2009
Nitrate Nitrogen0-200.5Chromotropic acid spectrophotometric method (EPA-recognized method)
Nitrite0-10.002GB/T 7493-1987
Residual Chlorine0-100.1HJ 586-2010
Total Chlorine0-100.1HJ586-2010
Chlorine Dioxide0-100.05DPD spectrophotometric method
Silica0-50.1HZ-HJ-SZ-0148
Volatile Phenols0-100.1HJ 503-2009
............

Related Products

VM-S550 Multi-Parameter Water Quality Analyzer VM-S550 Multi-Parameter Water Quality Analyzer
WKT-S550 Portable Multi-Parameter Water Quality Analyzer WKT-S550 Portable Multi-Parameter Water Quality Analyzer
VM-S550A COD Rapid Analyzer VM-S550A COD Rapid Analyzer
WKT-S550A Portable CCOD Rapid Analyzer WKT-S550A Portable CCOD Rapid Analyzer

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com