WKT-A2 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A2 Karl Fischer Trace Moisture Analyzer Coulometric

The VicoMeter WKT-A2 Entry-Level Karl Fischer moisture analyzer uses the coulometric (coulometry) principle to determine trace moisture, detecting water down to 1 ppm and measuring solids, liquids, and powders within one minute. It offers a friendly interface with a 240×64 blue LCD and full Chinese menus. Multiple built-in calculation formulas display results directly as % and ppm moisture, and a printer port supports an optional mini printer. It is widely used in chemicals, petroleum, pharmaceuticals, power, food, research, and testing.

Overview Technical Specifications Applicable Industries Related Products

Overview

WKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture AnalyzersWKT-A2 Karl FischercoulometricMoisture Analyzers

Technical Specifications

ModelWKT-A2
Measuring PrincipleKarl Fischercoulometric(coulometric)
Measurement Speed33.5 μg H2O/s (max)
Measuring Range2 μg H2O to 130 mg H2O
Measurement AccuracyError ≤ ±2 μg for water content below 10 μg; error ≤ ±5 μg for 10–500 μg water  (injection error excluded); standard deviation ≤ 0.2%
Resolution0.1μg H2O
Water Content (Concentration Range)1ppm-1000000ppm(0.0001%-100%)
Electrolysis Current0-400mA
Stirring SpeedStepless knob adjustment
Drift/Blank SubtractionAutomatic subtraction
Special FunctionsEnd-point delay, end-point detection, gain correction, electrolysis rate adjustment, and self-diagnostic fault alerts
Display & Operation240×64 blue LCD
Calendar/ClockCurrent time, date, and test time/date display
Endpoint IndicationScreen prompt / audible alarm / end-point lamp
Operating EnvironmentTemperature 2 ℃–50 ℃, humidity <90%
Power Consumption≤30W
Unit Dimensions285mm*300mm*220mm
Power Supply220V 50HZ 150W
WeightMain unit net weight 5 kg

Applicable Industries

Application Fields of the WKT-A2 Karl Fischer Trace Moisture Analyzer

LiquidChemical industry: alcohols, ethers, acids, benzenes, phenols, organic solvents, and other products suited to Karl Fischer determination.
         Petroleum and power: insulating oil, transformer oil, and other oils.
         Pharmaceutical industry: pharmaceutical raw materials, etc.
         Pesticide industry: emulsifiers, etc.
         Other industries: lithium battery electrolytes, etc.
SolidFreely soluble solids such as various inorganic salts and citric acid
GasGases such as nitrogen, SF6, natural gas, liquefied petroleum gas, Freon, and butadiene
The following industries require a Karl Fischer oven
Insoluble SolidsLithium batteries, plastics, medical, ceramic powders, metal powders, etc.
Other Insoluble SolidsInsoluble solids, easily contaminated and cross-contaminating samples (lubricating greases, aldehydes and ketones), samples that react with Karl Fischer reagent, and samples with slow moisture release

Related Products

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric
WKT-A9P ro Moisture Meter Coulometric WKT-A9P ro Moisture Meter Coulometric
WKT-A8 Automatic Moisture Analyzer Automatic Reagent Exchange WKT-A8 Automatic Moisture Analyzer Automatic Reagent Exchange
WKT-A7 Karl Fischer Moisture Titrator WKT-A7 Karl Fischer Moisture Titrator