WKT-A9-V2 Oil Moisture Analyzer

WKT-A9-V2 Oil Moisture Analyzer

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS

Overview Technical Specifications Applicable Industries More Related Products

Overview

WKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer CoulometricWKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Technical Specifications

ModelWKT-A9
Measuring PrincipleKarl Fischercoulometric(coulometric)
Measurement Speed40 μg H2O/s (max)
Measuring Range0.1μg-350mg
Measurement AccuracyError ≤ ±2 μg for water content of 100–1000 μg; error ≤ ±0.2% above 1000 μg (injection error excluded); standard deviation ≤ 0.3%
Resolution0.1μg H2O
Water Content (Concentration Range)0-100%
Electrolysis Current0–400 mA adjustable
Moisture Concentration Resolution0.001
Concentration Units%、ppm、mg/kg
Stirring SpeedStepless touch adjustment
Drift/Blank SubtractionAutomatic subtraction
Special FunctionsAutomatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts
Display & OperationColor touchscreen
Sample IDFreely configurable sample IDs
Stored Records500 records
PrintingBuilt-in low-power high-speed thermal printer, 56 mm paper width
PrintoutDisplays different content according to the user's measurement formulas and results
Calendar/ClockCurrent time, date, and test time/date displayed and printed
Endpoint IndicationScreen prompt / printout / audible alarm / end-point lamp
Operating EnvironmentTemperature 2 ℃–50 ℃, humidity <90%
Power Consumption≤50W
Unit Dimensions350mm*220mm*185mm
Power Supply220V 50HZ 150W
WeightMain unit net weight 4 kg, 7 kg packed

Applicable Industries

Application Fields of the WKT-V2-A9 Karl Fischer Trace Moisture Analyzer

LiquidChemical industry: alcohols, ethers, acids, benzenes, phenols, organic solvents, and other products suited to Karl Fischer determination.
Petroleum and power: insulating oil, transformer oil, and other oils.
Pharmaceutical industry: pharmaceutical raw materials, etc.
Pesticide industry: emulsifiers, etc.
Other industries: lithium battery electrolytes, etc.
SolidFreely soluble solids such as various inorganic salts and citric acid
GasGases such as nitrogen, SF6, natural gas, liquefied petroleum gas, Freon, and butadiene
The following industries require a Karl Fischer oven
Insoluble SolidsLithium batteries, plastics, medical, ceramic powders, metal powders, etc.
Other Insoluble SolidsInsoluble solids, easily contaminated and cross-contaminating samples (lubricating greases, aldehydes and ketones), samples that react with Karl Fischer reagent, and samples with slow moisture release

More

Application Fields of the WKT-V2-A9 Karl Fischer Trace Moisture Analyzer

LiquidChemical industry: alcohols, ethers, acids, benzenes, phenols, organic solvents, and other products suited to Karl Fischer determination.
         Petroleum and power: insulating oil, transformer oil, and other oils.
         Pharmaceutical industry: pharmaceutical raw materials, etc.
         Pesticide industry: emulsifiers, etc.
         Other industries: lithium battery electrolytes, etc.
SolidFreely soluble solids such as various inorganic salts and citric acid
GasGases such as nitrogen, SF6, natural gas, liquefied petroleum gas, Freon, and butadiene
The following industries require a Karl Fischer oven
Insoluble SolidsLithium batteries, plastics, medical, ceramic powders, metal powders, etc.
Other Insoluble SolidsInsoluble solids, easily contaminated and cross-contaminating samples (lubricating greases, aldehydes and ketones), samples that react with Karl Fischer reagent, and samples with slow moisture release

Related Products

WKT-C9 Karl Fischer Moisture Titrator Volumetric WKT-C9 Karl Fischer Moisture Titrator Volumetric
WKT-L-50ZS Online Microwave Liquid Moisture Analyzer WKT-L-50ZS Online Microwave Liquid Moisture Analyzer
VM-E01 Halogen Moisture Analyzer VM-E01 Halogen Moisture Analyzer
VM-E10 Halogen Moisture Analyzer VM-E10 Halogen Moisture Analyzer

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com