WKT-C30 Volumetric Karl Fischer Moisture Titrator

WKT-C30 Volumetric Karl Fischer Moisture Titrator

The WKT-C30 "fully automatic" Karl Fischer moisture analyzer uses the volumetric Karl Fischer principle to rapidly determine moisture down to 10 ppm, measuring solids, liquids, and powders within 30 seconds. Its RS232 port connects to printers, balances, computers, and other peripherals, and it stores 200 data sets with real-time query. A further upgrade of the Victor smart-series moisture analyzer, the C30 delivers a higher level of automation and precision. It complies with multiple national and international moisture standards as well as pharmacopoeia requirements and is widely used in chemicals, petroleum, pharmaceuticals, power, food, batteries, plastics, research, and testing.

Product Details Technical Specifications Applicable Industries Applications Related Products

Product Details

WKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Volumetric Karl Fischer Moisture TitratorWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture AnalyzersWKT-C30 Karl FischervolumetricMoisture Analyzers

Technical Specifications

ModelWKT-C30
Measuring PrincipleKarl Fischer Volumetric Titration
Moisture Range0.01-550 mg H2O
Measuring Range10 ppm-100% H2O
Metering Tube Resolution1/20000
Moisture Titration Repeatability≤0.005
Moisture Titration Linearity Correlation Coefficient≥0.999
Volumetric Error≤±0.0005
Relative Error≤0.5%
Measuring Range (Pure Water)10ppm ~100%
Signal Acquisition Resolution0.01ua
Minimum Dosing Volume0.001ml
Metering Tube Working Capacity24ml
Dosing Tube Accuracy±1/2000 per ml
Linear Repeatability>98.6%
Endpoint Delay5-99S adjustable
Titration Delay0-999 adjustable
Cleaning FunctionSupported, standby cleaning, shutdown cleaning
Ambient Temperature5℃ -40℃
Ambient Humidity≤80%
Output InterfaceRS232C
Power SupplyAC220V±10% 50HZ±2.5HZ
Weight3.5KG

Applicable Industries

LiquidChemical industry: alcohols, ethers, acids, benzenes, phenols, organic solvents, and other products suited to Karl Fischer determination.
            Petroleum and power industry: insulating oil, transformer oil, and other oil products.
            Pharmaceutical industry: pharmaceutical raw materials, etc.
            Pesticide industry: emulsifiers, etc.
            Other industries: lithium battery electrolytes, etc.
SolidFreely soluble solids such as various inorganic salts and citric acid
GasGases such as nitrogen, SF6, natural gas, liquefied petroleum gas, Freon, and butadiene
The following industries require a Karl Fischer oven
Insoluble SolidsLithium batteries, plastics, medical, ceramic powders, metal powders, etc.
Other Insoluble SolidsInsoluble solids, easily contaminated and cross-contaminating samples (lubricating greases, aldehydes and ketones), samples that react with Karl Fischer reagent, and samples with slow moisture release

Applications

WKT-C30 Applicable Standards

GB/T 11133-1989 "Determination of Water Content in Liquid Petroleum Products (Karl Fischer Method, Volumetric Method)"

GB/T 7380-1995 "Determination of Water Content in Surfactants (Karl Fischer Method, Volumetric Method)"

GB/T 6283-2008 Determination of Water Content in Chemical Products — Karl Fischer Method (General Method)

GB/T 606-2003 "General Method for Determination of Water in Chemical Reagents — Karl Fischer Method"

GB/T 10670-1989 "Determination of Trace Water in Fluoromethanes for Industrial Use — Karl Fischer Method"

GB/T 7376-2008 Determination of Trace Water in Fluorinated Alkanes for Industrial Use — Karl Fischer Method

ISO 10337-1997 Determination of Water in Crude Petroleum — Karl Fischer Method

GB/T 11146-2009 Determination of Water Content in Crude Oil — Karl Fischer Method

GB/T 3727-2003 Determination of Trace Water in Ethylene and Propylene for Industrial Use

GB/T 18826-2002 1,1,1,2-Tetrafluoroethane (HFC-134a) for Industrial Use

GB/T 18350-2001 "Denatured Fuel Ethanol"

GB/T 3776.1-1983 "Method for Determination of Water in Pesticide Emulsifiers"

GB/T 12717-2007 "Test Methods for Acetates for Industrial Use"

ASTM D4928-00 (2010) Determination of Water Content in Crude Oils by Coulometric Karl Fischer Titration

ASTM D6304-2007 Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration

GB/T 5074-1985 Microcoulometric Method for Determination of Water Content in Coking Products

GB/T 18619.1-2002 Determination of Water Content in Natural Gas — Coulometric Karl Fischer Method

GB/T 7600-1987 "Determination of Water Content in Transformer Oil in Service (Coulometric Method)"

SH/T 0246 "Determination of Water Content in Light Petroleum Products (Coulometric Method)"

GB/T 6023-1999 "Determination of Trace Water in Butadiene for Industrial Use — Coulometric Karl Fischer Method"

Complies with the technical requirements of the National Pharmacopoeia for the determination of water content in pharmaceuticals by the Karl Fischer method


Related Products

WKT-C9 Karl Fischer Moisture Titrator Volumetric WKT-C9 Karl Fischer Moisture Titrator Volumetric
WKT-C20 Volumetric Karl Fischer Moisture Titrator WKT-C20 Volumetric Karl Fischer Moisture Titrator
WKT-C20P ro Volumetric Karl Fischer Moisture Titrator WKT-C20P ro Volumetric Karl Fischer Moisture Titrator
WKT-C1 Automatic Karl Fischer Moisture Titrator WKT-C1 Automatic Karl Fischer Moisture Titrator

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com