WKT-C9 Karl Fischer Moisture Titrator Volumetric

WKT-C9 Karl Fischer Moisture Titrator Volumetric

The VicoMeter WKT-C9 fully automatic Karl Fischer moisture analyzer uses the volumetric Karl Fischer principle to rapidly determine moisture down to 10 ppm, measuring solids, liquids, and powders within 30 seconds. Its built-in RS232 port connects printers, balances, computers, and other peripherals, and it stores 200 data sets with real-time query. A further upgrade of the Victor smart-series moisture analyzer, the C9 delivers a higher level of automation and precision. It complies with multiple national and international moisture standards as well as pharmacopoeia requirements and is widely used in chemicals, petroleum, pharmaceuticals, power, food, batteries, plastics, research, and testing.

Overview Technical Specifications Applicable Industries Applications Related Products

Overview

WKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture AnalyzersWKT-C9Karl FischervolumetricMoisture Analyzers

Technical Specifications

ModelWKT-C9
Measuring PrincipleKarl Fischer Volumetric Method (Dead-Stop Titration)
Minimum Titration1μL (20ml burette)0.5μL (optional 10ml burette)
Measuring Range10ppm-100%
Moisture Range10μg-550mgH2O
Resolution1ppm
Polarization Current±1000μA
Burette Capacity20mL
Burette Accuracy5E-5(1/20000)mL
Titration Linearity Correlation Coefficient≥0.999
Custom Measurement MethodsUp to 10 groups
Display & Operation4.3-inch large LCD display with keypad input
Stirring SpeedStepless adjustment
Drift/Blank SubtractionDrift value measurable; freely set whether to deduct
Special FunctionsSeparate stirring stand, titration delay, endpoint determination delay, automatic cleaning, automatic operation, constant-temperature stirring (optional)
Number SettingUsers can freely set operator and sample numbers
Automatic CleaningOne-button cleaning functions including startup cleaning, shutdown cleaning, standby cleaning, pipeline cleaning and titration cell cleaning
Stored Records200 records
PrintingOptional external dedicated printer
Data CommunicationRS232 serial port for connecting peripheral devices
Calendar/ClockCurrent time, date and test time/date display and printout (GLP compliant)
Endpoint IndicationScreen prompt / audible warning / endpoint light indication / printout (printer required)
Operating EnvironmentTemperature 2 ℃–50 ℃, humidity <90%
Power Consumption≤50W
Unit Dimensions350mm*300mm*170mm
Power Supply220V 50HZ  150W
Weight12KG

Applicable Industries

Application Fields of the WKT-C9 Karl Fischer Moisture Analyzer

LiquidChemical industry: alcohols, ethers, acids, benzenes, phenols, organic solvents and other products suitable for Karl Fischer determination
         Petroleum and electric power industry: insulating oils, transformer oils and other oil products
         Pharmaceutical industry: pharmaceutical raw materials, etc.
         Pesticide industry: emulsifiers, fertilizers, pesticides, etc.; food and beverages, surfactants, cosmetics
         Other industries: lithium battery electrolytes, etc.
SolidVarious inorganic salts, citric acid, freeze-dried powders, pharmaceuticals and other highly soluble solids
GasGases such as nitrogen, SF6, natural gas, liquefied petroleum gas, Freon, and butadiene
The following industries require a Karl Fischer oven
Insoluble SolidsLithium batteries, plastics, medical, ceramic powders, metal powders, etc.
Other Insoluble SolidsInsoluble solids, easily contaminated and cross-contaminating samples (lubricating greases, aldehydes and ketones), samples that react with Karl Fischer reagent, and samples with slow moisture release

Applications

WKT-C9 Applicable Standards

GB/T 11133-1989 "Determination of Water Content in Liquid Petroleum Products (Karl Fischer Method, Volumetric Method)"

GB/T 7380-1995 "Determination of Water Content in Surfactants (Karl Fischer Method, Volumetric Method)"

GB/T 6283-2008 Determination of Water Content in Chemical Products — Karl Fischer Method (General Method)

GB/T 606-2003 "General Method for Determination of Water in Chemical Reagents — Karl Fischer Method"

GB/T 10670-1989 "Determination of Trace Water in Fluoromethanes for Industrial Use — Karl Fischer Method"

GB/T 7376-2008 Determination of Trace Water in Fluorinated Alkanes for Industrial Use — Karl Fischer Method

ISO 10337-1997 Determination of Water in Crude Petroleum — Karl Fischer Method

GB/T 11146-2009 Determination of Water Content in Crude Oil — Karl Fischer Method

GB/T 3727-2003 Determination of Trace Water in Ethylene and Propylene for Industrial Use

GB/T 18826-2002 1,1,1,2-Tetrafluoroethane (HFC-134a) for Industrial Use

GB/T 18350-2001 "Denatured Fuel Ethanol"

GB/T 3776.1-1983 "Method for Determination of Water in Pesticide Emulsifiers"

GB/T 12717-2007 "Test Methods for Acetates for Industrial Use"

ASTM D4928-00 (2010) Determination of Water Content in Crude Oils by Coulometric Karl Fischer Titration

ASTM D6304-2007 Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration

GB/T 5074-1985 Microcoulometric Method for Determination of Water Content in Coking Products

GB/T 18619.1-2002 Determination of Water Content in Natural Gas — Coulometric Karl Fischer Method

GB/T 7600-1987 "Determination of Water Content in Transformer Oil in Service (Coulometric Method)"

SH/T 0246 "Determination of Water Content in Light Petroleum Products (Coulometric Method)"

GB/T 6023-1999 "Determination of Trace Water in Butadiene for Industrial Use — Coulometric Karl Fischer Method"

Complies with the technical requirements of the National Pharmacopoeia for the determination of water content in pharmaceuticals by the Karl Fischer method


Related Products

WKT-C30 Volumetric Karl Fischer Moisture Titrator WKT-C30 Volumetric Karl Fischer Moisture Titrator
WKT-C20 Volumetric Karl Fischer Moisture Titrator WKT-C20 Volumetric Karl Fischer Moisture Titrator
WKT-C20P ro Volumetric Karl Fischer Moisture Titrator WKT-C20P ro Volumetric Karl Fischer Moisture Titrator
WKT-C1 Automatic Karl Fischer Moisture Titrator WKT-C1 Automatic Karl Fischer Moisture Titrator

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com