Rubber & Plastics

Solution for Measuring TPV Moisture Content with a Halogen Moisture Analyzer

How do you measure moisture content in TPV (thermoplastic vulcanizate) with a halogen moisture analyzer? This is a question of great concern to TPV suppliers and their customers alike. This article provides a moisture determination solution for a typical TPV sample. You will learn how to measure the moisture content of TPV samples with a halogen moisture analyzer, as well as the operating procedure and best practices for the VM-E01 rapid halogen moisture analyzer.

Introduction Related Products Related Knowledge Related Solutions
Need Help? Get a Quote

VM-E01 Halogen Moisture Analyzer(0.1mg/0.0001g)

VM-E01 Halogen Moisture Analyzer(0.1mg/0.0001g)

Background

Plastic part suppliers and their customers care about quality and fast production. Proper moisture in raw material ensures trouble-free compounding and molding, smooth surfaces, and ideal mechanical properties. The VicoMeter VM-E01 rapid halogen moisture analyzer is ideal for simple, accurate moisture measurement on the production floor.

Measuring moisture in plastics with a halogen moisture analyzer is a recognized ASTM method: D6980-12, "Standard Test Method for Determination of Moisture in Plastics by Loss in Weight".

VicoMeter is an expert in moisture testing, providing fast, targeted industry solutions. This article presents a moisture measurement solution for typical TPV (thermoplastic vulcanizate) samples: how to measure TPV moisture content with a halogen moisture analyzer, plus the operating procedure and best practices for the VM-E01 rapid halogen moisture analyzer.

Related Information

Before learning how to measure TPV (thermoplastic vulcanizate) moisture with the VM-E01 halogen moisture analyzer and its operating procedures, you may also want to know the following:

Common questions about TPV and plastics

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Reference Value Determination

In this test, the VicoMeter WKT-A9 Karl Fischer moisture analyzer was used to determine the reference moisture value of TPV (thermoplastic vulcanizate). Paired with the WKT-V2 Karl Fischer oven, the sample is transferred into the oven chamber and the released moisture is carried by dry nitrogen into the electrolytic cell for measurement.

Recommended Settings for Plastics Industry Samples

If you have no reference method for plastics samples on the VM-E01, VicoMeter recommends these settings from experimental experience:

  • Heating mode: Standard

  • Shutoff mode: Automatic (1 mg/140 s)

  • Sample size: 30 g

  • Resolution: High (0.1 mg/0.0001 g)

  • Warm-up: standby, 100°C; at standby temperature, preheat the empty pan for 1 minute, then tare.

Selecting the Drying Temperature

Same Sample Heated at Two Different Temperatures

Figure 1: Same Sample Heated at Different Temperatures

(Click image to enlarge)

Choose a drying temperature matching the Karl Fischer reference value. Melting or marked color change means the temperature is too high. Some samples inevitably discolor when heated (polyamide unavoidably turns brown).

Figure 1 compares samples after two heating runs. Left: correct temperature — no melting or discoloration. Right: the sample browned, so the temperature was too high.

Plastic Sample Handling

Measure samples promptly. Otherwise, fill the container completely (use a smaller one if needed) and seal it to minimize air and prevent moisture uptake during storage.

Procedure for measuring TPV (thermoplastic vulcanizate) samples with a halogen moisture analyzer

Place the VM-E01 rapid halogen moisture analyzer in a suitable location, switch it on and warm up for 30 min, level it (bubble centered), and perform weighing and temperature calibration. You can then start the TPV (thermoplastic vulcanizate) moisture measurement procedure (installation, operating environment, warm-up and calibration are covered inPreparation Before Formal Measurement with a Halogen Moisture Analyzeras discussed in that article; click the link to learn more.).

Halogen Moisture Analyzer Measurement Step: Taring

Tare Sample Pan

1. Place the empty pan on the center holder, preheat 1 min at 135°C standby, press tare to zero.

Halogen Moisture Analyzer Measurement Step: Spreading the Sample

Add Sample

2. Using a spatula, quickly and evenly spread about 30 g of TPV (thermoplastic vulcanizate) sample on the sample pan and wait for the reading to stabilize.

Halogen Moisture Analyzer Measurement Step: One-Touch Start

One-Touch Start

3. Once the reading is stable, press the start key. After a few minutes, the TPV (thermoplastic vulcanizate) moisture result is displayed on the screen.

Test Data

VM-E01 Halogen Moisture Analyzer(0.1mg/0.0001g)

VM-E01 Halogen Moisture Analyzer(0.1mg/0.0001g)

VM-E01 Settings Reference

  • Heating mode: Standard

  • Heating Temperature: 135°C

  • Shutoff mode: Automatic (1 mg/140 s)

  • Sample size: 30 g

  • Resolution: High (0.1 mg/0.0001 g)

  • Warm-up: standby, 100°C; at standby temperature, preheat the empty pan for 1 minute, then tare.

Sample Information

  • Sample description: TPV, beige, good chemical resistance, high/low temperature resistance, aging resistance, ozone resistance, recyclable

  • Typical maximum permissible moisture content [%]: 0.08

  • Hygroscopicity (23°C/50% rH) [%]: Not provided


Moisture measurement chart of TPV (thermoplastic vulcanizate) samples before and after drying

Moisture measurement chart of TPV (thermoplastic elastomer) samples before and after drying

Chart Notes

  • Recommendation: measure 6 TPV (thermoplastic vulcanizate) samples, each with a different moisture content (dry, moist).

  • Green line:Moisture content (average) measured with the WKT-A9 Karl Fischer moisture analyzer and WKT-V2 Karl Fischer oven.

  • Blue line:Moisture content (average) measured with the VM-E01 rapid halogen moisture analyzer.

  • Red line:Typical maximum allowable moisture for pellet processing; refer to the supplier's material-specific values.


Moisture measurement data of TPV (thermoplastic vulcanizate) samples before and after drying

Sample InformationMoisture content of the TPV sample before dryingMoisture content of the TPV sample after drying
Test MethodHalogen Moisture AnalyzerKarl Fischer Moisture AnalyzersHalogen Moisture AnalyzerKarl Fischer Moisture Analyzers
Moisture %MC0.2320.2220.0840.082
Std Dev Δ0.0020.0060.0030.001
Test Time [min]23301730

Sample-Specific Test Notes

Maximum allowable moisture for pellet processing must always follow supplier specifications. Values here are typical only and may not suit your material or process.

These drying parameters were obtained on common plastics and do not cover all grades or colors; optimizing them may be needed for best results on a specific material.

FAQ

Can the Loss-on-Drying Method Measure Plastics?

Yes. Measuring moisture in plastics with a halogen moisture analyzer is a recognized ASTM method: D6980-12, "Standard Test Method for Determination of Moisture in Plastics by Loss in Weight".

Can a Rapid Halogen Moisture Analyzer Replace the Oven Method for Plastics?

Yes — seeCan Rapid Halogen Moisture Analyzers Replace the Oven Method?).

Can the same method for unreinforced plastics be used on reinforced plastics?

Yes — reinforced plastics contain glass or other materials that do not affect moisture measurement.

Can colorless-resin parameters be applied to a colored resin?

Adjust drying temperature for heat absorption — e.g., black resin about 10°C lower than white.

How to measure moisture in plasticized plastics?

Take care: loss on drying counts volatilized plasticizer as moisture. Heat at a lower temperature where possible to prevent plasticizer loss.

Can I apply my Karl Fischer oven temperature to the VM-E01?

Not directly. As a rule of thumb, the VM-E01 drying temperature is about 30°C lower than the oven's.

Can a method developed for one supplier's polymer be used on the same polymer type from other suppliers?

It is a good reference, but should be adapted to the other suppliers' polymer compounds.

Dr. Wei's Classroom

Thermoplastic vulcanizate (TPV); in Chinese it is also abbreviated as thermoplastic rubber (TPR), but this name is easily confused with other thermoplastic elastomers (TPE), because TPEs are also commonly called thermoplastic rubber—especially styrenic elastomers. At least in China, "TPR" seems to have become their proprietary name: when people say TPR, they mean TPEs based on styrenic elastomers such as SBS and SEBS, inseparable from the huge consumption of styrenic elastomers in civilian and end-consumer products.

Related Products

VM-E01 Halogen Moisture Analyzer VM-E01 Halogen Moisture Analyzer
VM-E10 Halogen Moisture Analyzer VM-E10 Halogen Moisture Analyzer
VM-E20 Halogen Moisture Analyzer VM-E20 Halogen Moisture Analyzer
VM-E50 Halogen Moisture Analyzer VM-E50 Halogen Moisture Analyzer
VM-01S Halogen Moisture Analyzer VM-01S Halogen Moisture Analyzer
VM-1S Halogen Moisture Analyzer VM-1S Halogen Moisture Analyzer
VM-2S Halogen Moisture Analyzer VM-2S Halogen Moisture Analyzer
VM-5S Halogen Moisture Analyzer VM-5S Halogen Moisture Analyzer

Related Knowledge

Halogen Moisture Analyzer Halogen Moisture Analyzer

The halogen moisture analyzer is also known as a rapid halogen moisture meter, halogen moisture measuring instrument, halogen moisture tester, halogen moisture gauge, moisture tester, moisture meter, water content meter, moisture check meter, and more.

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

Karl Fischer Oven Karl Fischer Oven

A Karl Fischer oven is a heating device used together with a Karl Fischer moisture analyzer. It is commonly used to extract moisture from samples and assist the Karl Fischer moisture analyzer in testing the moisture content of samples. The Karl Fischer oven is also called a KF oven, KF auxiliary heating device, Karl Fischer heating unit, Karl Fischer heating furnace, Karl Fischer drying oven, gas-phase moisture extractor, or Karl Fischer sample heating oven.

Related Solutions

Solution for Determining the Moisture Content of TPU Material with a Halogen Moisture Analyzer Solution for Determining the Moisture Content of TPU Material with a Halogen Moisture Analyzer

How to determine the moisture content in TPU (thermoplastic polyurethane) with a halogen moisture analyzer? This is a question of great concern to TPU (thermoplastic polyurethane) suppliers and their customers. This article provides a moisture determination solution for typical TPU (thermoplastic polyurethane) samples. You will learn how to use a halogen moisture analyzer to determine the moisture content of TPU samples, as well as the operating procedures and specifications of the VM-E01 rapid halogen moisture analyzer.

Solution for Determining the Moisture Content of PMMA Material with a Halogen Moisture Analyzer Solution for Determining the Moisture Content of PMMA Material with a Halogen Moisture Analyzer

How to determine the moisture content in PMMA (polymethyl methacrylate) with a halogen moisture analyzer? This is a question of great concern to PMMA suppliers and their customers. This article provides a moisture determination solution for typical PMMA (polymethyl methacrylate) samples. You will learn how to use a halogen moisture analyzer to determine the moisture content of PMMA samples, as well as the operating procedures and specifications of the VM-E01 rapid halogen moisture analyzer.

Solution for Determining the Moisture Content of PET Material with a Halogen Moisture Analyzer Solution for Determining the Moisture Content of PET Material with a Halogen Moisture Analyzer

How to determine the moisture content in PET (polyethylene terephthalate) with a halogen moisture analyzer? This is a question of great concern to PET suppliers and their customers. This article provides a moisture determination solution for typical PET (polyethylene terephthalate) samples. You will learn how to use a halogen moisture analyzer to determine the moisture content of PET samples, as well as the operating procedures and specifications of the VM-E01 rapid halogen moisture analyzer.

Solution for Determining the Moisture Content of PBT Material with a Halogen Moisture Analyzer Solution for Determining the Moisture Content of PBT Material with a Halogen Moisture Analyzer

How to determine the moisture content in PBT (polybutylene terephthalate) with a halogen moisture analyzer? This is a question of great concern to PBT suppliers and their customers. This article provides a moisture determination solution for typical PBT (polybutylene terephthalate) samples. You will learn how to use a halogen moisture analyzer to determine the moisture content of PBT samples, as well as the operating procedures and specifications of the VM-E01 rapid halogen moisture analyzer.

Solution for Determining the Moisture Content of PA66 Material with a Halogen Moisture Analyzer Solution for Determining the Moisture Content of PA66 Material with a Halogen Moisture Analyzer

How to determine the moisture content in PA66 (Nylon 66, Nylon 66 resin, Polyamide 66, polyhexamethylene adipamide, Polyamide 66, Nylon 6.6) with a halogen moisture analyzer? This is a question of great concern to PA66 suppliers and their customers. This article provides a moisture determination solution for typical PA66 samples. You will learn how to use a halogen moisture analyzer to determine the moisture content of PA66 samples, as well as the operating procedures and specifications of the VM-E01 rapid halogen moisture analyzer.

Solution for Determining the Moisture Content of PA6 Material with a Halogen Moisture Analyzer Solution for Determining the Moisture Content of PA6 Material with a Halogen Moisture Analyzer

How to determine the moisture content in PA6 (Nylon 6, Polyamide 6, Polycaprolactam) with a halogen moisture analyzer? This is a question of great concern to PA6 (Nylon 6, Polyamide 6, Polycaprolactam) suppliers and their customers. This article provides a moisture determination solution for typical PA6 (Nylon 6, Polyamide 6, Polycaprolactam) samples. You will learn how to use a halogen moisture analyzer to determine the moisture content of PA6 (Nylon 6, Polyamide 6, Polycaprolactam) samples, as well as the operating procedures and specifications of the VM-E01 rapid halogen moisture analyzer.

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com