Customer Profile

The instrument commissioned for the customer this time was the A7 coulometric Karl Fischer moisture analyzer. The VicoMeter WKT-A7 Fully Automatic Trace Moisture Analyzer integrates a number of advanced patented technologies. Its measurement principle is the world-recognized classic method for moisture determination [coulometric Karl Fischer method], with a measurement range down to 0.0001% (1ppm). It can rapidly determine moisture content in liquids, solids, and gases within 60 seconds and is widely used in the chemical, petroleum, power, research, and railway industries, where moisture content is one of the key indicators of product quality. Multiple built-in moisture calculation formulas meet the needs of different users; equipped with a high-efficiency micro printer and a large-capacity memory storing up to 500 test records, its convenient retrieval allows users to easily review and print test reports.

WKT-A7 Karl Fischer Moisture Titrator

WKT-A7 Karl Fischer Moisture Titrator

WKT-A7 Karl Fischer Moisture Titrator

Coulometric (coulometry) principle, ideal for trace-level testing; 7-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


VicoMeter at the Customer Site

The customer had previously used a Karl Fischer moisture analyzer themselves, but the response time was long and repeatability was poor. Upon arriving at Shaanxi Licai Pharmaceutical Co., Ltd., the VicoMeter technical engineer first inspected the instrument the customer had installed and found that the electrolysis electrode and measuring electrode were plugged in reversed, and that the customer's Karl Fischer reagent had expired. The customer's operator also reported that they did not know how to use automatic liquid aspiration and drainage. The A7 is an automated Karl Fischer moisture analyzer with automatic aspiration and drainage; to activate these functions, the power switch must be flipped to the opposite side.

After resolving these minor issues, the VicoMeter technical engineer prepared to run tests for the customer, only to learn that the customer's sample was a lyophilized powder with a moisture content of 1%–5%. A coulometric Karl Fischer moisture analyzer is a trace moisture tester: it electrolytically generates iodine, which reacts with water, and the moisture content is calculated from the electricity consumed. When the moisture content is too high, electrolysis takes a long time, and prolonged electrolysis heats the electrolysis electrode, affecting measurement accuracy. Although the coulometric Karl Fischer analyzer can measure the moisture in lyophilized powder, it is not the optimal choice. After hearing our explanation, the customer understood and ultimately used a volumetric Karl Fischer moisture analyzer to test the lyophilized powder.

Different samples require different instruments, and every sample has its own characteristics. If customers are not familiar with these differences, it is better to choose a professional company that can provide a professional solution.

Customer Profile

WKT-A7 Karl Fischer Moisture Titrator

Licai Pharmaceutical

(Click image to enlarge)

Licai Pharmaceutical

Licai Pharmaceutical Co., Ltd. (hereinafter 'Licai Pharmaceutical') is a subsidiary of Shaanxi Licai Industrial Group. Founded in 1993, Shaanxi Licai Industrial Group Co., Ltd. is committed to providing customers with high-quality, full-range products and services under the business philosophy of 'openness, mutual trust, integration, and coexistence'. After 30 years of substantial development, it has initially formed a 'one core, six wings' business structure with real estate development as the core, complemented by commercial operations, hotel management, pharmaceutical technology, financial investment, culture and education, and cultural tourism and wellness. It strives to build a full-range life service chain encompassing quality residential communities, new commercial complexes, high-end business hotels, Chinese and Western pharmaceutical R&D, and a quality education system, with 5 million m2 of developed and constructed area and 1 million m2 of self-held commercial and hotel properties under independent operation. Several Wanda Plazas — Licai, Qindu, and Sanyuan — operated in cooperation with Wanda Group have become the most vibrant commercial centers and landmarks in their cities. Multiple star projects in Xianyang co-developed with Sunac (China) have won wide market acclaim and high recognition from owners. Licai is a co-builder of better cities and a creator of quality living. Guided by the corporate vision of 'becoming an outstanding quality-of-life service provider' and upholding the corporate values of 'the great way leads far', Licai is building a comprehensive service system for a happy and healthy life.

Founded in 2003, Licai Pharmaceutical Co., Ltd. is a specialized pharmaceutical enterprise focused on drug R&D, production, and sales, with the corporate mission of 'serving human health, improving quality of life, and creating a happy life', and is committed to becoming a forerunner in the development of China's pharmaceutical industry. Licai Pharmaceutical operates two production bases, one R&D center, and one sales company, with 159 products under independent intellectual property rights and more than 800 employees, and its sales continue to grow steadily.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

Related Cases

Zhenghe Medical
Hande Chuanghong Biochemical Technology
Lunan Pharmaceutical
Zhongke Meiling
Shaanxi Lvdun Institute of Environmental Engineering
Shenzhen Qianyan Pharmaceutical R&D Technology
Chia Tai Tianqing Pharmaceutical Group Co., Ltd.
Shenzhen Weizhijun Biotechnology

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com