Lunan Pharmaceutical

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Customer Profile

Lunan Pharmaceutical purchased two WKT-C9 Karl Fischer moisture analyzers from us. The WKT-C9 Karl Fischer moisture titrator is a volumetric Karl Fischer moisture titrator designed and developed in-house with independent intellectual property rights — a Karl Fischer moisture analyzer for mid-to-high-end applications.

WKT-C9 Karl Fischer Moisture Titrator Volumetric

WKT-C9 Karl Fischer Moisture Titrator Volumetric

WKT-C9 Karl Fischer Moisture Titrator Volumetric

The VicoMeter WKT-C9 fully automatic Karl Fischer moisture analyzer uses the volumetric Karl Fischer principle to rapidly determine moisture down to 10 ppm, measuring solids, liquids, and powders within 30 seconds. Its built-in RS232 port connects printers, balances, computers, and other peripherals, and it stores 200 data sets with real-time query. A further upgrade of the Victor smart-series moisture analyzer, the C9 delivers a higher level of automation and precision. It complies with multiple national and international moisture standards as well as pharmacopoeia requirements and is widely used in chemicals, petroleum, pharmaceuticals, power, food, batteries, plastics, research, and testing.


VicoMeter at the Customer Site

The two Karl Fischer moisture analyzers purchased by Lunan Pharmaceutical from VicoMeter were installed in Workshops No. 52 and No. 53. This was VicoMeter's first cooperation with Lunan Pharmaceutical. After confirming the schedule with Lunan Pharmaceutical, the VicoMeter technical engineer officially arrived on site on March 4, 2019, and the installation was completed smoothly.

Many pharmaceutical companies require 3Q qualification, and we encountered a problem during the 3Q qualification process: the customer had previously used a pipette for testing — simply entering the sample volume gave the moisture content — but the WKT-C9 defaults to the gravimetric method, meaning the sample weight must be entered to obtain the moisture content. After communicating with our design department, the VicoMeter technical engineer suggested that the customer purchase a balance dedicated for use with the pipette to solve this problem. However, after internal discussions, Lunan Pharmaceutical considered this approach infeasible because their final moisture result had to be expressed in ML/100ML. The VicoMeter technical engineer then urgently held a phone and video conference with our software engineers to discuss a solution. Together they found that the units in our algorithm could be modified — the volume could simply be entered where the weight was originally input. After reaching a consensus with Lunan Pharmaceutical, the engineer verified this method with 95% alcohol, and the test results proved it feasible. In the end, the VicoMeter technical engineer successfully completed the installation of both moisture analyzers for Lunan Pharmaceutical.

On-site installations always come with a series of challenges, but with the joint efforts of the VicoMeter team, we can always provide customers with a moisture measurement solution that fits their needs.

Customer Profile

Lunan Pharmaceutical

New Times Pharmaceutical Co., Ltd. is a national-level key high-tech enterprise. It operates a national-level enterprise technology development center and a postdoctoral research workstation, has jointly established the Luhua Biotechnology Research Institute with East China University of Science and Technology, and has jointly established the Shanda-Lunan Natural Medicine Research Institute and the Shanda-Lunan Supercritical Fluid Technology Research Institute with Shandong University. Its drug analysis center is equipped with precision analytical instruments that rank among the leading level in the domestic industry.

Related Products

Related Knowledge

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

Related Cases

Zhenghe Medical
Hande Chuanghong Biochemical Technology
Zhongke Meiling
Shaanxi Lvdun Institute of Environmental Engineering
Chia Tai Tianqing Pharmaceutical Group Co., Ltd.
Shenzhen Weizhijun Biotechnology
Shanghai Tellgen Life Science Co., Ltd.
Qingdao Shuangyuan Taihe Pharmaceutical