Feimiao Optoelectronic Technology

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Feimiao Optoelectronic Technology
Feimiao Optoelectronic Technology
Feimiao Optoelectronic Technology
  • Feimiao Optoelectronic Technology
  • Feimiao Optoelectronic Technology
  • Feimiao Optoelectronic Technology

Customer Profile

Femto Photonics purchased the WKT-A3 Karl Fischer trace moisture analyzer. The WKT-A3 "Vision" Karl Fischer trace moisture analyzer uses the coulometric Karl Fischer principle to rapidly determine trace moisture down to 1 ppm in solids, liquids and powders within one minute, with built-in printing. Compliant with multiple national and international moisture determination standards, the WKT-A3 includes eight moisture calculation formulas and six measurement methods for all industries, and is widely used in chemical, petroleum, pharmaceutical, power, food, research and testing sectors.

WKT-A3 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A3 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A3 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle; 5.7-inch display with keypad operation and automatic calculation; measuring range 1 ppm–100%; 200 automatically stored results with history query at any time; complies with multiple national standards and suits virtually every industry.

  • 5 moisture determination methods to cover your everyday sample testing

  • Dual-CPU data processing design for stable, precise computation

  • Instrument status, error, and fault self-check functions help users handle unexpected situations


VicoMeter at the Customer Site

Upon arrival, our engineer first went through the packing list with the customer, then proceeded directly to installation and customer training. The customer's sample was isopropanol, which is produced by hydrogenating acetone, so different processes result in different acetone contents. If the acetone content is low, ordinary pyridine-free Karl Fischer reagent can be used; but if the acetone content is high, an aldehyde/ketone reagent is required—otherwise aldehydes and ketones in the sample react with methanol in an acetalization reaction that produces water and seriously interferes with the test.

The customer's sample contained little aldehyde/ketone content, so our engineer used ordinary pyridine-free coulometric Karl Fischer reagent. Three tests gave results of 0.0722%, 0.0681% and 0.0705%—stable results meeting the customer's requirements.

Customer Profile

WKT-A3 Karl Fischer Trace Moisture Analyzer Coulometric

Feimiao Optoelectronic Technology

(Click image to enlarge)

Feimiao Optoelectronic Technology

Femto Photonics Technology (Xi'an) Co., Ltd. was established on July 4, 2001. Its general business scope covers the R&D, production and sale of optoelectronic materials, devices and equipment, optical communication components and equipment, biomedical optical instruments, computers and peripherals, and software; opto-mechatronic systems and engineering; and technical consulting, technology transfer and development services, as well as import and export of goods and technology (except those prohibited or restricted by the state).

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Murata New Energy (Wuxi)
Jiangxi Jinglikang New Material Technology
Chongqing Jiabaocheng Energy Technology
Jiweida (Shanghai) Electric
HKC Group
Hisense Home Appliances
Ganzhou Ruifute Technology Co., Ltd.
Anhui Keda Clean Energy New Material Co., Ltd.

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com