Jiangxi Jinglikang New Material Technology

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Jiangxi Jinglikang New Material Technology
  • Jiangxi Jinglikang New Material Technology

Customer Profile

The customer purchased the VicoMeter WKT-A9 "Exquisite" Karl Fischer moisture analyzer. Using the coulometric Karl Fischer principle, the WKT-A9 rapidly determines trace moisture down to 0.001 ppm in solids, liquids and powders within one minute. The instrument features built-in printing, storage for 500 data sets, and real-time query and printing. Innovative guided prompts and a built-in electronic manual make operation simple. Compliant with multiple national and international moisture determination standards, the WKT-A9 includes eight moisture calculation formulas and six measurement methods for all industries, and is widely used in chemical, petroleum, pharmaceutical, power, food, research and testing sectors—a Karl Fischer moisture analyzer for mid-to-high-end applications.

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


VicoMeter at the Customer Site

Because the customer's company had just been founded, their laboratory was not yet complete and its temperature and humidity could not meet installation requirements. Upon arrival, the VicoMeter engineer assessed the conditions and, after consulting with the customer's management, temporarily installed the instrument in the office; the customer would move it to the laboratory once completed. The engineer then checked the instrument accessories with the customer's responsible person and, after confirmation, began installation.

The installation went smoothly. Afterwards, the engineer ran verification tests with 0.1 µL, 0.2 µL, 0.3 µL, 0.5 µL, 1 µL and 2 µL of deionized water, and all results were within range. Testing then began with the customer's sample (the sample name cannot be disclosed for confidentiality reasons). Using a disposable syringe, the engineer first rinsed and wetted the syringe and needle with the sample. Because the sample's moisture content was very low, a larger portion was taken; after sampling, the dedicated No. 9 needle was attached, wiped, and the assembly weighed and tared on the balance. The engineer pressed start-injection, immersed the needle below the liquid surface and injected the sample. Three tests on the same sample gave stable results close to third-party values, and the customer was very satisfied. Since the sample was black, the engineer advised the customer to pour the reagent into a separate bottle for storage after each test.

Customer Profile

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Jiangxi Jinglikang New Material Technology

(Click image to enlarge)

Jiangxi Jinglikang New Material Technology

Jiangxi Jinglikang New Material Technology Co., Ltd., founded in February 2020 and located in the Ganzhou Port Electronic Information Industrial Park, Nankang District, Ganzhou, specializes in the R&D, production and sale of carbon nanotubes, graphene, conductive liquids, and electrically and thermally conductive composite materials, holding core intellectual property in carbon nanotubes and graphene.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Murata New Energy (Wuxi)
Chongqing Jiabaocheng Energy Technology
Jiweida (Shanghai) Electric
HKC Group
Hisense Home Appliances
Ganzhou Ruifute Technology Co., Ltd.
Feimiao Optoelectronic Technology
Anhui Keda Clean Energy New Material Co., Ltd.

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com