Guangdong Tenglong Chemical Technology Co., Ltd.

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Guangdong Tenglong Chemical Technology Co., Ltd.
Guangdong Tenglong Chemical Technology Co., Ltd.
Guangdong Tenglong Chemical Technology Co., Ltd.
Guangdong Tenglong Chemical Technology Co., Ltd.
  • Guangdong Tenglong Chemical Technology Co., Ltd.
  • Guangdong Tenglong Chemical Technology Co., Ltd.
  • Guangdong Tenglong Chemical Technology Co., Ltd.
  • Guangdong Tenglong Chemical Technology Co., Ltd.

Customer Profile

The customer uses the VicoMeter WKT-A9 Precision Karl Fischer trace moisture analyzer, which applies the coulometric Karl Fischer (coulometry) principle to rapidly determine trace moisture in samples.

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


VicoMeter at the Customer Site

For on-site verification, since no 0.5 μL imported syringe was available at the time, a 2 μL pure-water test was performed directly to avoid experimental deviation. The measurement returned 2023.65 μg, and the customer's own operation returned 2072.99 μg — the instrument passed. The customer's sample was high-concentration acrylic acid, with a reference water content of 0.05% from earlier data, tested from a bottled sample dated November 16. After repeated hands-on measurements by the engineer and the customer, the water content read 0.069% with good stability and little variation across injection volumes; the customer understood that the long storage time may have raised the moisture slightly.

Dr. Wei's Classroom

Acrylic acid is used in resin manufacture, synthetic rubber latex production, and many other fields. Acrylic fibers are overwhelmingly used for clothing, decorative products, artificial fur, and other textiles, with little used elsewhere. Industrially, acrylic acid mainly goes into acrylate esters (resins) — about 60% of total consumption — applied in construction, papermaking, leather, textiles, plastics processing, packaging materials, consumer chemicals, water treatment, oil recovery, and metallurgy.

Customer Profile

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Guangdong Tenglong Chemical Technology Co., Ltd.

(Click image to enlarge)

Guangdong Tenglong Chemical Technology Co., Ltd.

Founded on September 8, 2011, Guangdong Tenglong Chemical Technology Co., Ltd. produces and sells papermaking chemicals and engages in their wholesale business. Dongguan Tenglong is Chengming Chemical's Dongguan production base; its current main product is acrylic acid.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Nanhai Chemical
Zhejiang Donghai New Materials
Nantong Tenglong Chemical Technology
Zhongfu New Water Source Technology
Anhui Haihua Technology Co., Ltd.
Guangyuan Ruifeng New Materials
Suzhou Meichen New Materials
Hunan Shengya Sports Industry

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com