Customer Profile

The customer purchased three VicoMeter WKT-A9 Precision Karl Fischer moisture analyzers. The VicoMeter WKT-A9 Precision Karl Fischer trace moisture analyzer uses the coulometric Karl Fischer (coulometry) principle to rapidly measure trace moisture in samples, detecting water down to 0.001 ppm and determining trace moisture in solids, liquids, and powders within one minute. The built-in printer and storage for 500 data sets allow real-time query and printout. Innovative guided prompts and a built-in e-manual make operation simple. The WKT-A9 complies with multiple national and international moisture standards and provides eight built-in moisture calculation formulas and six determination methods to meet the moisture testing needs of every industry. Widely used in chemicals, petroleum, pharmaceuticals, power, food, research, and testing, it is a Karl Fischer moisture analyzer built for mid-to-high-end applications.

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


VicoMeter at the Customer Site

The customer bought three WKT-A9 Precision Karl Fischer trace moisture analyzers at one time for use across its three plants, mainly testing oil samples with moisture around 300–500 ppm. They had previously used the density method, which gave large errors and poor stability. During on-site installation and commissioning, the VicoMeter engineers recommended switching to the mass method, which is unaffected by density and bubbles and gives stable results. They also advised using disposable syringes paired with our dedicated needles: the syringe was rinsed 3–5 times before testing, then 0.4 mL of sample was run in three tests, yielding 421 ppm, 449 ppm, and 437 ppm — accurate, stable results that satisfied the customer.

Customer Profile

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Jiangsu Hualun Chemical Co., Ltd.

(Click image to enlarge)

Jiangsu Hualun Chemical Co., Ltd.

Jiangsu Hualun Chemical Co., Ltd. was founded on January 6, 1997. Its business scope covers the production and sale of high-boiling aromatic solvents (SA-1000, SA-1500, SA-2000), aromatic plasticizers, propylene glycol methyl ether, propylene glycol methyl ether acetate, dipropylene glycol methyl ether, dipropylene glycol ethyl ether, polyol ethers, and C10 heavy aromatics; hazardous chemical production and distribution (per the relevant licenses); sale of chemical products and raw materials (excluding hazardous goods and pesticides); self-run or agency import/export of goods and technology; equipment leasing; and rental of owned premises.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Nanhai Chemical
Zhejiang Donghai New Materials
Nantong Tenglong Chemical Technology
Zhongfu New Water Source Technology
Anhui Haihua Technology Co., Ltd.
Guangyuan Ruifeng New Materials
Hubei Shanshui Chemical
Zibo Jieyuan Chemical

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com