Zibo Jieyuan Chemical

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Zibo Jieyuan Chemical
Zibo Jieyuan Chemical
Zibo Jieyuan Chemical
  • Zibo Jieyuan Chemical
  • Zibo Jieyuan Chemical
  • Zibo Jieyuan Chemical

Customer Profile

The customer purchased our VicoMeter WKT-C30 fully automatic Karl Fischer moisture analyzer. The WKT-C30 “Fully Automatic” Karl Fischer moisture analyzer uses the Karl Fischer volumetric principle to quickly determine moisture in samples, measuring moisture as low as 10 ppm. It can determine moisture in solids, liquids, and powders within 30 seconds. The instrument has a built-in RS232 serial port for connecting printers, balances, computers, and other peripheral devices, and can store 200 sets of data with real-time query!

WKT-C30 Volumetric Karl Fischer Moisture Titrator

WKT-C30 Volumetric Karl Fischer Moisture Titrator

WKT-C30 Volumetric Karl Fischer Moisture Titrator

The WKT-C30 "fully automatic" Karl Fischer moisture analyzer uses the volumetric Karl Fischer principle to rapidly determine moisture down to 10 ppm, measuring solids, liquids, and powders within 30 seconds. Its RS232 port connects to printers, balances, computers, and other peripherals, and it stores 200 data sets with real-time query. A further upgrade of the Victor smart-series moisture analyzer, the C30 delivers a higher level of automation and precision. It complies with multiple national and international moisture standards as well as pharmacopoeia requirements and is widely used in chemicals, petroleum, pharmaceuticals, power, food, batteries, plastics, research, and testing.


VicoMeter at the Customer Site

On arrival, the VicoMeter engineer unpacked and checked the accessories — nothing missing — and began the installation, which went smoothly. Because the customer's samples are crude oil, which does not dissolve directly in methanol, xylene had to be added to the methanol as a co-solvent, and the ratio must be controlled carefully: too much co-solvent keeps the instrument from reaching the end point and ruins the test, so the co-solvent proportion must never exceed 3:7. The engineer set the end-point current to 50 μA. Five calibrations gave 3.32,  3.37,  3.31,  3.35, and  3.29 — stable results. Three sample tests then returned 51.2%, 50.9%, and 51.5% — stable, accurate data. The customer was very satisfied with both the VicoMeter instrument and the service.

Customer Profile

WKT-C30 Volumetric Karl Fischer Moisture Titrator

Zibo Jieyuan Chemical

(Click image to enlarge)

Zibo Jieyuan Chemical

Zibo Jieyuan Chemical Co., Ltd. was founded on November 17, 2014. Its business scope (within the licensed scope of its hazardous chemicals operating permit) covers chemicals, chemical raw materials, ceramic raw materials, ethylene tar, water treatment products, feed materials, composite materials, fiber products, glass fiber products, cement raw materials, steel materials, slag, ore powder, electromechanical products, labor protection articles, chemical equipment, instruments and meters, plastic products, office supplies, wallpaper, petroleum machinery equipment and accessories, hardware and building materials, steel, electrical appliances, electronic equipment, office equipment, wires and cables, valves, insulation materials, industrial automation equipment, pipes and fittings, plus petroleum technical services.

Related Products

Related Knowledge

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

Related Cases

Hubei Shanshui Chemical
Shanghai Yichen Chemical Materials
Hunan Shengya Sports Industry
Suzhou Meichen New Materials
Guangyuan Ruifeng New Materials
Anhui Haihua Technology Co., Ltd.
Zhongfu New Water Source Technology
Nantong Tenglong Chemical Technology

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com