Beijing Shuanglu Pharmaceutical Co., Ltd.

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Beijing Shuanglu Pharmaceutical Co., Ltd.
Beijing Shuanglu Pharmaceutical Co., Ltd.
Beijing Shuanglu Pharmaceutical Co., Ltd.
Beijing Shuanglu Pharmaceutical Co., Ltd.
  • Beijing Shuanglu Pharmaceutical Co., Ltd.
  • Beijing Shuanglu Pharmaceutical Co., Ltd.
  • Beijing Shuanglu Pharmaceutical Co., Ltd.
  • Beijing Shuanglu Pharmaceutical Co., Ltd.

Customer Profile

Beijing SL Pharmaceutical Co., Ltd. purchased the VicoMeter WKT-A9 'Exquisite' Karl Fischer Moisture Analyzer together with the matching WKT-V2 Karl Fischer oven. Based on the coulometric Karl Fischer principle, the VicoMeter WKT-A9 'Exquisite' trace moisture analyzer rapidly determines trace moisture in samples down to 0.001ppm, and can measure trace moisture in solids, liquids, and powders within 1 minute. The instrument features a built-in printer and can store 500 sets of data for real-time query and printing. Innovative navigation-style prompts and a built-in electronic manual make operation effortless. Complying with multiple national and international moisture determination standards, the WKT-A9 includes eight built-in moisture calculation formulas and six determination methods to meet the needs of various industries. It is widely used in the chemical, petroleum, pharmaceutical, power, food, research, and testing industries, making it a Karl Fischer moisture analyzer for mid-to-high-end applications.

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


WKT-V2 Karl Fischer Oven Moisture Measurement System

WKT-V2 Karl Fischer Oven Moisture Measurement System

WKT-V2 Karl Fischer Oven Moisture Measurement System

When measuring moisture with a Karl Fischer analyzer, most samples can be added directly to the generator cell/titration cell for simple, accurate testing. Some samples, however, cannot be added directly because their moisture is not released naturally or they undergo side reactions with the Karl Fischer reagent — for example powders, granules, pastes, and oxidizing inorganic salts.

For samples that cannot be added directly to the cell, pairing the WKT-V2 Karl Fischer oven for gas-phase extraction is the perfect solution. The sample is placed in a vial and moved onto the oven, heated to a specific temperature (up to 300˚C), and the moisture is extracted and carried into the cell by dry air or nitrogen, then measured perfectly.


VicoMeter at the Customer Site

Beijing SL Pharmaceutical purchased the VicoMeter WKT-A9 Karl Fischer Moisture Analyzer and WKT-V2 Karl Fischer oven mainly for testing the moisture content of lyophilized powder pharmaceuticals. The customer had not performed any testing since June, and the reagent had been left in the bottle, causing the drying tube and electrode to become stuck. After cleaning the reaction vessel and electrode and drying them for use, we trained the customer on maintenance. The customer's reagent had expired, and we also discussed re-purchasing the related accessories and consumables with the customer. The equipment usage records were normal.

Customer Profile

WKT-V2 Karl Fischer Oven Moisture Measurement System

Beijing Shuanglu Pharmaceutical Co., Ltd.

(Click image to enlarge)

Beijing Shuanglu Pharmaceutical Co., Ltd.

SL Pharmaceutical (002038) is the first high-tech enterprise from the capital to list on the SME Board of the Shenzhen Stock Exchange. Since its founding in 1994, leveraging its technological strengths and continuous innovation, the company has developed and marketed more than 70 products with independent intellectual property rights, including three national Class I new drugs. It has won one second prize of the National Science and Technology Progress Award and nine first, second, and third prizes of the Beijing Science and Technology Progress Award. Closely following changes in the disease spectrum, the company has built a rich product pipeline in the fields of hematology, oncology, cardiovascular and cerebrovascular diseases, liver disease, diabetes, and kidney disease. The company has independently applied for and received funding from the national "863" Program four times. The company and its chairman Xu Mingbo were honored with the 'Outstanding Contribution Award' at Zhongguancun's 20th Anniversary of Innovation and Development.

The company is a key high-tech enterprise of the National Torch Program, one of the first 'Top 100 Innovative Enterprises' in Haidian Park of Zhongguancun Science Park, one of the first outstanding enterprises and second-phase key cultivation enterprises of the 'Beijing Biomedical Industry Leapfrog Development Project' (G20 Project), a Beijing 'Intellectual Property Pilot Unit', and the industrialization base for four national "863" Program achievements, with a national-level enterprise technology center. In 2012, Chairman Xu Mingbo was named one of the 'Top 100 Leading Talents in Science and Technology in Beijing'; in 2014, he was named a Science and Technology Figure at the 3rd Capital Science and Technology Festival and a figure promoting 'Created in Beijing'. The company has established a subsidiary in the United States to conduct innovative drug research and operates advanced monoclonal antibody and biopharmaceutical R&D and production bases internationally. Its genetic engineering products have been successfully exported to nearly 20 countries, steadily advancing the company's internationalization strategy.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Qingdao Shuangyuan Taihe Pharmaceutical
Licai Pharmaceutical
Shanghai Tellgen Life Science Co., Ltd.
Shenzhen Weizhijun Biotechnology
Chia Tai Tianqing Pharmaceutical Group Co., Ltd.
Shenzhen Qianyan Pharmaceutical R&D Technology
Shaanxi Lvdun Institute of Environmental Engineering
Zhongke Meiling

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com