Zhengzhou Lansen Biotechnology

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Zhengzhou Lansen Biotechnology
Zhengzhou Lansen Biotechnology
Zhengzhou Lansen Biotechnology
  • Zhengzhou Lansen Biotechnology
  • Zhengzhou Lansen Biotechnology
  • Zhengzhou Lansen Biotechnology

Customer Profile

Lansen Biotechnology purchased the VicoMeter WKT-A9 'Exquisite' Karl Fischer trace moisture analyzer together with the matching WKT-V1 Karl Fischer oven. Based on the coulometric Karl Fischer principle, the VicoMeter WKT-A9 'Exquisite' rapidly determines trace moisture in samples down to 0.001ppm, and can measure trace moisture in solids, liquids, and powders within 1 minute. The instrument features a built-in printer and can store 500 sets of data for real-time query and printing. Innovative navigation-style prompts and a built-in electronic manual make operation effortless. Complying with multiple national and international moisture determination standards, the WKT-A9 includes eight built-in moisture calculation formulas and six determination methods to meet the needs of various industries. It is widely used in the chemical, petroleum, pharmaceutical, power, food, research, and testing industries.

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


WKT-V2 Karl Fischer Oven Moisture Measurement System

WKT-V2 Karl Fischer Oven Moisture Measurement System

WKT-V2 Karl Fischer Oven Moisture Measurement System

When measuring moisture with a Karl Fischer analyzer, most samples can be added directly to the generator cell/titration cell for simple, accurate testing. Some samples, however, cannot be added directly because their moisture is not released naturally or they undergo side reactions with the Karl Fischer reagent — for example powders, granules, pastes, and oxidizing inorganic salts.

For samples that cannot be added directly to the cell, pairing the WKT-V2 Karl Fischer oven for gas-phase extraction is the perfect solution. The sample is placed in a vial and moved onto the oven, heated to a specific temperature (up to 300˚C), and the moisture is extracted and carried into the cell by dry air or nitrogen, then measured perfectly.


VicoMeter at the Customer Site

When the VicoMeter technical engineer arrived at the customer's site, the customer had not yet decided where to install the instrument. After reviewing the laboratory together, they found only one fume hood, which already contained instruments, so other instruments could not fit inside and had to be placed outside. However, the reagents used in the Karl Fischer moisture analyzer must not be exposed to direct sunlight, so the instrument had to be placed further inside the laboratory. Once the installation location was confirmed, the engineer began installing the instrument. After installation, the engineer ran a test with pure water: 2ul of pure water gave a result of 1997ug. After the pure-water verification, tests were performed with the customer's lyophilized sample. With the WKT-V1 set to 105℃ and a delay time of 100S, two tests were run, giving results of 2.12% and 2.28%. The customer also ran two tests with the sample, obtaining 2.21% and 2.18%. The four results showed good repeatability and stability, and the customer was very satisfied with the VicoMeter instrument.

Customer Profile

WKT-V2 Karl Fischer Oven Moisture Measurement System

Zhengzhou Lansen Biotechnology

(Click image to enlarge)

Zhengzhou Lansen Biotechnology

Zhengzhou Lansen Biotechnology Co., Ltd. was established on July 7, 2004, with its registered address at Rooms 20–22, 4th Floor, Building 3, No. 36 Hongsong Road, Zhengzhou High-Tech Zone, and its legal representative is Meng Lin. Its business scope includes Class I and II medical devices and Class III clinical laboratory analytical instruments; production of in vitro diagnostic reagents [6840]; research, development, and consulting services for biotechnology and related products; and sales of fine chemical products and testing reagents (excluding items prohibited by national laws and regulations or subject to approval). Zhengzhou Lansen Biotechnology Co., Ltd. has invested in one company and has one branch.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Zhenghe Medical
Hande Chuanghong Biochemical Technology
Lunan Pharmaceutical
Zhongke Meiling
Shaanxi Lvdun Institute of Environmental Engineering
Shenzhen Qianyan Pharmaceutical R&D Technology
Chia Tai Tianqing Pharmaceutical Group Co., Ltd.
Shenzhen Weizhijun Biotechnology

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com