Beijing Guodian Electric Power Co., Ltd.

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Beijing Guodian Electric Power Co., Ltd.
Beijing Guodian Electric Power Co., Ltd.
Beijing Guodian Electric Power Co., Ltd.
Beijing Guodian Electric Power Co., Ltd.
  • Beijing Guodian Electric Power Co., Ltd.
  • Beijing Guodian Electric Power Co., Ltd.
  • Beijing Guodian Electric Power Co., Ltd.
  • Beijing Guodian Electric Power Co., Ltd.

Customer Profile

Beijing Guodian Power Co., Ltd. purchased the VicoMeter WKT-A9 precision Karl Fischer moisture analyzer and a volume resistivity tester. The WKT-A9 Karl Fischer titrator is a coulometric Karl Fischer moisture titrator independently designed and developed by our company with proprietary intellectual property rights—a Karl Fischer moisture analyzer aimed at mid-to-high-end applications.

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


VicoMeter at the Customer Site

After the VicoMeter technical engineer arrived on site, the instrument and accessories were first unpacked and checked with the customer, then installation began. After installation, the engineer verified the instrument with the customer using pure water, testing with 100 ug, 200 ug, 500 ug and 1000 ug. The engineer's results were 102.13 ug, 199.66 ug, 488.22 ug and 1019.68 ug; the customer's results were 100.85 ug, 199.6 ug, 497.50 ug and 953.95 ug. All results were within the permitted error range. The engineer then demonstrated actual operation using the customer's oil sample. After the moisture analyzer installation and commissioning was completed, the volume resistivity instrument was installed, and the engineer demonstrated how to test with a single sample and with three samples.

Customer Profile

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Beijing Guodian Electric Power Co., Ltd.

(Click image to enlarge)

Beijing Guodian Electric Power Co., Ltd.

Guodian Power Development Co., Ltd. is a core listed power company controlled by CHN Energy and the integration platform for its conventional energy generation business, with operations spanning thermal power, hydropower, wind power, solar power, coal, chemicals and other fields across 24 provinces, municipalities and autonomous regions—the second largest listed power company in China. Guided by the group's latest strategic positioning and its basic working approach, the company is steadily advancing healthy and sustainable development.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Shanghai Qigao
Xiya Lubricants (Shanghai)
Ningbo Yongjia Transformer
Zeller+Gmelin Corporation, Germany
Sinopec
Jiweida (Shanghai) Electric
Guangzhou Muqiao Auto Parts Co., Ltd.
Nanjing Silai Robotics Co., Ltd.

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com