Zhejiang Qianlong New Materials Co., Ltd.
Zhejiang Qianlong New Material Co., Ltd. purchased five VicoMeter devices this time: the VM-E01 halogen moisture analyzer, AC series electronic balance, WKT-400C melt flow indexer, muffle furnace, and tensile tester. A VicoMeter technical engineer visited their site to install and commission them.
0.0001 g (0.1 mg) weighing accuracy, 0.001% readability, electromagnetic force weighing sensor, PT-1000 high-precision platinum-rhodium temperature sensor, touchscreen operation, halogen lamp heating, custom methods, and history data storage.
First in the industry to combine temperature calibration and weight calibration.
Simple operation — one-touch start, reliable results.
Upgraded ring halogen lamp: fast heat-up, even heating, long service life
Custom determination methods for different industries and sample types
Display modes including but not limited to MC%, DC%, AM%, and AD%.
Complies with international oven-method moisture determination standards
RS232 interface for connection to a PC, printer, PLC, or LIMS
VicoMeter weighing technology delivers accurate measurement results. AC series balances provide fast, accurate readings, and internal calibration offers a quick one-touch balance calibration method.
A clear, intuitive interface gives direct access to all operating programs and daily calibration; combined with easy cleaning, your daily tasks become fast and efficient, supporting your everyday work.
Fully automatic internal calibration: the balance calibrates itself whenever the ambient temperature changes by ≥1.5 ℃ or when ≥2 hours have passed since the last calibration.
Keeps your weighing results accurate and reliable with fewer unnecessary steps. Built to last — thanks to the AC series' robust design, high-quality materials ensure dependable, accurate results for years to come, throughout the instrument's entire life cycle.
The WKT-400C melt flow indexer (melt indexer) integrates the mass-based (MFR) and volume-based (MVR) methods in one instrument, with push-button operation and an integrated manual/automatic cutting design. Designed and manufactured to authoritative standards, it determines the melt flow rate (MFR and MVR) of various plastics and resins in the viscous flow state. It is suitable for engineering plastics with high melting temperatures such as polycarbonate, polyarylsulfone, fluoroplastics and nylon, as well as plastics with lower melting temperatures such as polyethylene (PE), polystyrene (PS), polypropylene (PP), ABS resin, polyoxymethylene (POM) and polycarbonate (PC) resin. It is widely used in plastics production, plastic products, petrochemicals and other industries, as well as in universities, research institutes and commodity inspection departments.
After arriving at the customer's site, the VicoMeter technical engineer checked the electrical connections and found that none of the laboratory bench sockets were grounded. The engineer informed the customer, who later rewired the grounding themselves.
The balance and halogen moisture analyzer worked normally after calibration; the halogen analyzer was used to test wood powder moisture and passed verification. For the melt flow indexer, the customer tested PE plastic pellets at 190°C with a 2,160 g load using the mass method; the test result was 0.9 g/10min, below the customer's required standard of 1 g.
During installation of the muffle furnace, one heating tube broke. A replacement was sought on the market, but no suitable matching part was available. The company was contacted and re-sent 2 tubes; upon arrival they were installed, and the furnace powered on normally. It reached the set temperature of 800°C in less than 30 minutes. The customer placed the muffle furnace on the floor for now and planned to prepare an iron rack as a base later; the customer was advised to install an exhaust system.
The tensile machine molds arrived later. The customer tested wood-plastic boards measuring 50 cm in length, 14 cm in width, and 2.4 cm in thickness. Testing showed the flexural force reached 4,634 N, while the customer's standard only required above 2,500 N.
The above equipment passed installation and inspection. The customer's laboratory is being set up before the end of the year, with formal production starting next year and dedicated personnel to be recruited for the laboratory work. This operation training was conducted for temporary substitute staff; all equipment operation has been covered in the training
Zhejiang Qianlong New Material Co., Ltd., established on May 10, 2021, with a business scope including general items: new material technology promotion services; technical services, technology development, technical consulting, technology exchange, technology transfer, and technology promotion; sales of plastic products; sales of lightweight building materials; wholesale of hardware products; retail of hardware products; sales of bamboo products; landscaping engineering construction; professional design services; agricultural horticulture services; sales of doors and windows; metal door and window engineering construction; production and sales of environmentally friendly wood-plastic composite profiles.