Lanzhou University

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Lanzhou University
Lanzhou University
Lanzhou University
  • Lanzhou University
  • Lanzhou University
  • Lanzhou University

Customer Profile

Lanzhou University purchased the VicoMeter WKT-A9 Karl Fischer moisture analyzer and WKT-V2 Karl Fischer oven.

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


WKT-V2 Karl Fischer Oven Moisture Measurement System

WKT-V2 Karl Fischer Oven Moisture Measurement System

WKT-V2 Karl Fischer Oven Moisture Measurement System

When measuring moisture with a Karl Fischer analyzer, most samples can be added directly to the generator cell/titration cell for simple, accurate testing. Some samples, however, cannot be added directly because their moisture is not released naturally or they undergo side reactions with the Karl Fischer reagent — for example powders, granules, pastes, and oxidizing inorganic salts.

For samples that cannot be added directly to the cell, pairing the WKT-V2 Karl Fischer oven for gas-phase extraction is the perfect solution. The sample is placed in a vial and moved onto the oven, heated to a specific temperature (up to 300˚C), and the moisture is extracted and carried into the cell by dry air or nitrogen, then measured perfectly.


Customer Profile

WKT-V2 Karl Fischer Oven Moisture Measurement System

Lanzhou University

(Click image to enlarge)

Lanzhou University

Lanzhou University is a national key university directly under the Ministry of Education of the PRC, with a vice-ministerial structure under central administration, co-built by the State Administration of Science, Technology and Industry for National Defense and the Ministry of Education. It is listed in the "Double First-Class", "985 Project" and "211 Project", and selected for the "Everest Plan", "Strong Foundation Plan", "2011 Plan", "111 Plan", the Excellent Legal Talent, Excellent Doctor and Excellent Agriculture and Forestry Talent education programs, the National Innovative Experiment Program for College Students, the National College Student Innovation and Entrepreneurship Training Program, the national high-level university graduate study-abroad program, the New Engineering program, the Chinese Government Scholarship program for international students, and the national demonstration university for innovation and entrepreneurship education reform. It is among the first Chinese universities authorized to confer bachelor's, master's and doctoral degrees and to establish postdoctoral stations, a member of the Sino-Russian Comprehensive University Alliance [69]  , an institution with independent degree authorization review, and a council member of the China AI Education Association.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Related Cases

Chinese Academy of Sciences
Tianjin University
East China University of Science and Technology
State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology
Guangdong Medical University
Anhui University of Chinese Medicine
Huazhong University of Science and Technology (State Key Laboratory of Coal Combustion)
Xi'an University of Architecture and Technology

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com