Customer Profile

Shandong Zhushi Pharmaceutical Group purchased the VicoMeter WKT-A9 Karl Fischer Moisture Analyzer together with the matching WKT-V2 Karl Fischer oven. The WKT-A9 Karl Fischer moisture titrator is a coulometric Karl Fischer moisture titrator designed and developed in-house with independent intellectual property rights. The WKT-V2 Karl Fischer oven is the fourth-generation Karl Fischer oven refined through multiple improvements by Jiangsu Victor Instrument Meter Co., Ltd., featuring a more user-friendly and streamlined touch operating system. Paired with our dedicated moisture analyzer, the VicoMeter 'Volcano' series WKT-V2 Karl Fischer oven is suitable for moisture determination of all kinds of insoluble samples (battery materials, plastics and rubber, lubricating greases, pharmaceutical materials, new materials, moisture-regain-prone samples, and samples with volatile components), and has been well applied in the plastics, battery, new materials, medical, and electronics industries!

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A9 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle, ideal for trace-level testing; 5-inch color touchscreen with smart operation, automatic result calculation, and freely configurable sample IDs; complies with multiple national standards and suits virtually every industry.

  • 8 moisture calculation formulas, 6 determination methods, and 8 end-point detection algorithms

  • Automatic drift compensation, automatic subtraction of ambient and background moisture, and self-diagnostic fault alerts

  • One-touch start for reliable results

  • Outstanding automation — connects seamlessly to the Karl Fischer oven for difficult samples

  • RS232 interface for connection to a PC, printer, PLC, or LIMS


WKT-V2 Karl Fischer Oven Moisture Measurement System

WKT-V2 Karl Fischer Oven Moisture Measurement System

WKT-V2 Karl Fischer Oven Moisture Measurement System

When measuring moisture with a Karl Fischer analyzer, most samples can be added directly to the generator cell/titration cell for simple, accurate testing. Some samples, however, cannot be added directly because their moisture is not released naturally or they undergo side reactions with the Karl Fischer reagent — for example powders, granules, pastes, and oxidizing inorganic salts.

For samples that cannot be added directly to the cell, pairing the WKT-V2 Karl Fischer oven for gas-phase extraction is the perfect solution. The sample is placed in a vial and moved onto the oven, heated to a specific temperature (up to 300˚C), and the moisture is extracted and carried into the cell by dry air or nitrogen, then measured perfectly.


VicoMeter at the Customer Site

Shandong Zhushi Pharmaceutical Group purchased the VicoMeter Karl Fischer moisture analyzer mainly to test moisture in medical sutures. According to the customer's industry standard YY 1116-2020, testing medical sutures requires a coulometric Karl Fischer moisture analyzer and a Karl Fischer oven.

The customer had essentially completed the instrument assembly before the VicoMeter technical engineer arrived. Upon arrival, the engineer first inspected the customer's installation and found it generally fine, though various small details — such as the instrument's airtightness — were not done well enough; the engineer fixed all of these issues one by one. The engineer then standardized the instrument with pure water: first the A9 was equilibrated, then the V2 was connected to the A9. After the instrument equilibrated again, 2ul of pure water was injected into the sample boat, giving a result of 1986ug. The customer was very satisfied. The customer then brought out their sample; the engineer set the Karl Fischer oven to 140℃ with a delay time of 150S and ran the test, giving a result of 1121PPM. Since sampling was not performed inside a glove box, the result was within the customer's acceptable range.

Shandong Zhushi Pharmaceutical Group

Customer Profile

WKT-V2 Karl Fischer Oven Moisture Measurement System

Shandong Zhushi Pharmaceutical Group

(Click image to enlarge)

Shandong Zhushi Pharmaceutical Group

Shandong Zhushi Pharmaceutical Group Co., Ltd. is registered at Fanlou Road South, Shanxian Development Zone, registered with the Shanxian Market Supervision Administration, with Zhu Kunfu as its legal representative. Its business scope includes general items: production and sales of Class I medical devices; sales of Class II medical devices; sales of hygiene products and single-use medical supplies; sales of disinfectants (excluding hazardous chemicals); sales of special labor protection supplies; software development; wholesale and retail of cosmetics; sales of personal hygiene products; internet sales (except goods requiring a license); sales and R&D of household appliances; technical services, technology development, technical consulting, technology exchange, technology transfer, and technology promotion; sales of daily necessities; and sales of labor protection supplies.

Related Products

Related Knowledge

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Qingdao Shuangyuan Taihe Pharmaceutical
Licai Pharmaceutical
Shanghai Tellgen Life Science Co., Ltd.
Shenzhen Weizhijun Biotechnology
Chia Tai Tianqing Pharmaceutical Group Co., Ltd.
Shenzhen Qianyan Pharmaceutical R&D Technology
Lunan Pharmaceutical
Zhongke Meiling

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com