Customer Profile

Jiangxi People Power Transmission & Transformation Co., Ltd. purchased our WKT-A3 "Vision" Karl Fischer trace moisture analyzer. The WKT-A3 uses the coulometric Karl Fischer principle to rapidly determine trace moisture down to 1 ppm in solids, liquids and powders within one minute, with built-in printing. Compliant with multiple national and international moisture determination standards, the WKT-A3 includes eight moisture calculation formulas and six measurement methods for all industries, and is widely used in chemical, petroleum, pharmaceutical, power, food, research and testing sectors.

WKT-A3 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A3 Karl Fischer Trace Moisture Analyzer Coulometric

WKT-A3 Karl Fischer Trace Moisture Analyzer Coulometric

Coulometric (coulometry) principle; 5.7-inch display with keypad operation and automatic calculation; measuring range 1 ppm–100%; 200 automatically stored results with history query at any time; complies with multiple national standards and suits virtually every industry.

  • 5 moisture determination methods to cover your everyday sample testing

  • Dual-CPU data processing design for stable, precise computation

  • Instrument status, error, and fault self-check functions help users handle unexpected situations


VicoMeter at the Customer Site

Upon arrival, the VicoMeter engineer contacted the customer's purchasing staff, who had the laboratory manager escort him to the lab. The instrument was still sealed; engineer and customer unpacked it together, checking accessories along the way. The reagent showed slight discoloration but remained usable, so the engineer proceeded with installation. After installation, verification was performed with pure water at 0.1 µL, 0.2 µL, 0.5 µL and 1 µL, while the engineer explained operating precautions. Results were 99.5 µg, 200.8 µg, 507.3 µg and 980.5 µg; the customer's results were 99.2 µg, 201 µg, 491 µg and 976.9 µg. Having no balance, the customer tested by the density method, obtaining 17 ppm both times.

Customer Profile

WKT-A3 Karl Fischer Trace Moisture Analyzer Coulometric

Jiangxi Renmin Power Transmission & Transformation Co., Ltd.

(Click image to enlarge)

Jiangxi Renmin Power Transmission & Transformation Co., Ltd.

Jiangxi People Power Transmission & Transformation Co., Ltd., located in Nanchang, Jiangxi, is a wholly owned company of People Electric Appliance Group with total investment of RMB 1.8 billion and over 1,000 mu of land—one of the state's key power equipment enterprises. It mainly develops and manufactures power transformers up to 500 kV, dry-type transformers, amorphous alloy transformers and box-type substations, as well as special rectifier transformers up to 330 kV. Its products are widely used in the State Grid, transportation, urban construction, petrochemical, metallurgical and mining projects, featuring short-circuit resistance, low loss, low noise, low emissions, low temperature rise and leak-free operation, with all indicators at internationally advanced levels. The customer purchased our WKT-A3 moisture analyzer. The WKT-A3 "Vision" Karl Fischer trace moisture analyzer uses the coulometric Karl Fischer principle to rapidly determine trace moisture down to 1 ppm in solids, liquids and powders within one minute, with built-in printing. Compliant with multiple national and international moisture determination standards, the WKT-A3 includes eight moisture calculation formulas and six measurement methods for all industries, and is widely used in chemical, petroleum, pharmaceutical, power, food, research and testing sectors.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Beijing Guodian Electric Power Co., Ltd.
Jiangsu Yawei Transformer
Hangzhou Electrochemical Group Co.
Alxa League Jinbaolige Mining
Henan Keyuan Electronic Aluminum Foil
Feimiao Optoelectronic Technology
State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology
Huazhong University of Science and Technology (State Key Laboratory of Coal Combustion)

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com