Nanjing Haijing Pharmaceutical

Case Study Related Products Related Knowledge Related Cases
Need Help? Get a Quote

VicoMeter On-site Training

Nanjing Haijing Pharmaceutical
Nanjing Haijing Pharmaceutical
Nanjing Haijing Pharmaceutical
Nanjing Haijing Pharmaceutical
  • Nanjing Haijing Pharmaceutical
  • Nanjing Haijing Pharmaceutical
  • Nanjing Haijing Pharmaceutical
  • Nanjing Haijing Pharmaceutical

Customer Profile

The customer purchased a VicoMeter WKT-C1 Karl Fischer Moisture Analyzer. Based on the volumetric Karl Fischer principle, the WKT-C1 'Intelligent' rapidly determines moisture in samples down to 10ppm and can measure the moisture of solids, liquids, and powders within 30 seconds. The WKT-C1 Intelligent Karl Fischer Moisture Analyzer is a fully automatic moisture analysis system jointly developed by the R&D department of Jiangsu Victor Instrument Meter Co., Ltd. and the 53rd Research Institute of China North Industries Group. The instrument has a built-in RS232 serial port for connecting printers, balances, computers, and other peripherals, and can store 200 sets of data for real-time query. The WKT-C1's detachable 7-inch LCD capacitive touch screen integrates a micro Windows system with powerful functions, operation prompts, and flexible human-machine interaction. In 2010, with the help of ultra-precision displacement measurement technology from the State Key Laboratory of Precision Measurement Technology and Instruments at Tsinghua University, the WKT-C1 titration system was further improved, and its measurement accuracy has been further enhanced ever since.

WKT-C1 Automatic Karl Fischer Moisture Titrator

WKT-C1 Automatic Karl Fischer Moisture Titrator

WKT-C1 Automatic Karl Fischer Moisture Titrator

The WKT-C1 "Smart" Karl Fischer moisture analyzer is a fully automatic moisture analysis system jointly developed by VicoMeter's R&D department and the 53rd Research Institute of China North Industries Group. Using the volumetric principle, it measures moisture down to 10 ppm and determines solids, liquids, and powders within 30 seconds. Its RS232 port connects printers, balances, computers, and other peripherals; it stores 100 data sets; and its separate 7-inch capacitive touchscreen runs an embedded micro Windows system — powerful, with clear operation prompts and flexible user interaction. In 2010, with help on ultra-precision displacement measurement from the State Key Laboratory of Precision Measurement Technology and Instruments at Tsinghua University, the WKT-C1 titration system was further improved, raising its measurement accuracy once again. The WKT-C1 complies with multiple national and international moisture standards and with pharmacopoeia requirements and is widely used in chemicals, petroleum, pharmaceuticals, power, food, batteries, plastics, research, and testing.


VicoMeter at the Customer Site

After arriving at the customer's site, the VicoMeter technical engineer first checked the instrument's accessory list with the customer and began installation after confirming everything was in order.

The customer had used VicoMeter instruments before, so they also helped with the installation. By the time the VicoMeter technical engineer finished assembling the main unit, the customer had already helped install the other parts. After installation, the engineer prepared to demonstrate the operation, but the customer was already familiar with the basic procedures, so the engineer switched approaches and had the customer demonstrate instead. The customer skillfully performed blank titration, standardization, and sample testing with standard steps and proficient technique; the error of five standardizations was less than 0.1, and the pure-water verification gave a moisture result of 99.6%. The results were accurate, and the customer was very satisfied.

Customer Profile

WKT-C1 Automatic Karl Fischer Moisture Titrator

Nanjing Haijing Pharmaceutical

(Click image to enlarge)

Nanjing Haijing Pharmaceutical

Nanjing Haijing Pharmaceutical Co., Ltd., formerly Nanjing Cod Liver Oil Factory — one of the three earliest cod liver oil factories in China — is a technology-innovation enterprise integrating pharmaceutical R&D, production, and sales.

Located in the Nanjing High-Tech Development Zone of Jiangsu Province, the company operates five production lines for soft capsules, oral solutions, emulsions, syrups, and sprays, all of which have passed the 2014 revised GMP certification.

The company mainly produces vitamins and pediatric oral liquid preparations. With a sound quality management and innovation system, the company has made its operations scientific, standardized, and efficient. It has established a development strategy centered on customers and patients, guided by the market, focused on superior products, and aimed at efficiency and scale.

Relying on Aige Bio's strong research capabilities and fruitful achievements, the company has initiated more than a dozen new pediatric oral liquid drug projects that are marketed abroad but not yet available in China, which will be launched successively in the coming years. The company also owns a series of achievements, including Class I new drugs with independent intellectual property rights, laying the foundation for Haijing's long-term development.

Upholding a corporate culture in which technology creates the future and learning leads development, and adhering to the philosophy that products begin with design, the company develops and promotes precise, safe, and effective high-quality medicines to safeguard the health of Chinese children.

Related Products

Related Knowledge

Karl Fischer Moisture Analyzers Karl Fischer Moisture Analyzers

A Karl Fischer moisture analyzer is an instrument designed on the Karl Fischer method to measure moisture content in materials. It is also known as a Karl Fischer moisture meter, fully automatic Karl Fischer moisture titrator, intelligent Karl Fischer trace moisture analyzer, or Fischer-method moisture meter, and comes in two types: coulometric and volumetric (titrimetric).

What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration? What Is the Difference Between Coulometric and Volumetric Karl Fischer Titration?

The biggest difference between the volumetric and coulometric methods is that I2differ in their source: in the volumetric method, I2comes from the titrant reagent, while in the coulometric method, I2is produced by electrolyzing an electrolyte containing I-is generated by electrolysis of the electrolyte.

Which Samples Can a Karl Fischer Moisture Analyzer Test? Which Samples Can a Karl Fischer Moisture Analyzer Test?

As a classic moisture determination method, Karl Fischer titration is suitable for measuring water in a wide range of organic and inorganic substances. Because compounds vary in their properties, they fall into two categories: those that can be analyzed directly and those that cannot.

What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination? What Calibration Standards and Verification Methods Are Available for Karl Fischer Moisture Determination?

VicoMeter Karl Fischer moisture analyzers are typically calibrated and verified using standards such as methanol-water standard solutions, water-containing sodium tartrate, distilled (deionized or pure) water, and water-saturated toluene. This article introduces the calibration substances, calibration methods, and accuracy verification procedures commonly used with VicoMeter coulometric and volumetric Karl Fischer moisture analyzers.

How to Ensure Moisture Reacts Fully with Karl Fischer Reagent How to Ensure Moisture Reacts Fully with Karl Fischer Reagent

As a professional instrument for moisture determination, the Karl Fischer moisture analyzer is widely used across industries. Ensuring that moisture reacts fully with the Karl Fischer reagent is the key to accurate moisture measurement in samples. How can this be achieved? That is the question this article answers. As an expert in the moisture field, VicoMeter walks you through it.

Measuring Sample Moisture with a Karl Fischer Moisture Analyzer Measuring Sample Moisture with a Karl Fischer Moisture Analyzer

The Karl Fischer moisture analyzer rapidly determines trace moisture in samples and is the most professional method for moisture content determination.

Related Cases

Zhenghe Medical
Hande Chuanghong Biochemical Technology
Lunan Pharmaceutical
Zhongke Meiling
Shaanxi Lvdun Institute of Environmental Engineering
Shenzhen Qianyan Pharmaceutical R&D Technology
Chia Tai Tianqing Pharmaceutical Group Co., Ltd.
Shenzhen Weizhijun Biotechnology

Customized solutions for your real business needs

Contact

Recently Viewed Products

Contact
+8652389989770
+8613852641385
sales@vicometer.com